  • A high-purity 20MHz DDS function generator designed for engineers requiring precision signal output, advanced modulation, and digital control.

    Key Features:

    • Frequency range: 0.001Hz to 20MHz
    • High resolution: 6 digits or 1mHz
    • Excellent stability (1ppm) and 10ppm one-year accuracy
    • Digital control for phase-continuous sweep (linear or logarithmic)
    • Output range: 5mV to 20V peak-to-peak from 50 or 600 Ohms
    • Low distortion sine wave with high spectral purity
    • Built-in modulation: AM, FSK, gated mode, tone switching
    • Store and recall multiple instrument setups
    • USB and RS232 interfaces for remote control

     

  • A high-performance 20MHz DDS function generator offering precise waveform control, high spectral purity, and flexible remote interfacing.

    Key Features:

    • Frequency range: 0.001Hz to 20MHz
    • High resolution: 6 digits or 1mHz
    • Frequency stability: ±1ppm, accuracy: ±10ppm
    • Ultra-low distortion sine waves with high spectral purity
    • Internal linear/log sweep with phase continuity
    • Built-in AM, FSK, gated, and tone-switching modes
    • Output: 5mV to 20V pk-pk from 50Ω or 600Ω
    • Store and recall multiple instrument set-ups
    • USB and RS232 interfaces for remote programming

     

  • High-performance dual-channel function and arbitrary waveform generator with up to 240 MHz output for advanced test and signal needs.

    Key Features:

    • Frequency range from 40 MHz to 240 MHz
    • Dual independent or coupled full-performance channels
    • Precise phase control: 0.001° resolution
    • Arbitrary waveform support up to 800 MS/s
    • Replay rates up to 80 MHz
    • Wide range of built-in and user-defined waveforms
    • Pulse generation up to 100 MHz, low jitter
    • Internal/external modulation, sweep, gated, and burst modes
    • USB, LAN (LXI compliant), and optional GPIB
    • PC software for waveform generation and editing

     

  • Key Features:

    • Wide temperature range from -65°C to +300°C
    • Compatible with 150mm, 200mm, and 300mm wafer sizes
    • Options for mechanical refrigeration, glycol/water, or air cooling
    • Heating methods: ThermoElectric or Resistive, depending on model
    • Retrofits available for existing probe stations
    • Customizable surface plating: gold or nickel
    • Supports advanced applications like low leakage probing (fA level) and high-voltage probing (up to 10kV)

     

  • ThermoSpot Systems – Benchtop Direct Contact Cooling and Heating Solution

    The Temptronic® ThermoSpot® delivers high-performance temperature control for IC testing and high-Watt devices with unmatched cooling capacity.

    Key Features:

    • Reliable thermal cycling without thermoelectric modules
    • Wide temperature range: -65°C to +175°C
    • Cooling power: 40W at -40°C, 55W at -55°C, 120W at -40°C
    • Fast transitions: <35 seconds from +25°C to -40°C
    • Secure thermal contact with ThermoBridge™ design
    • Touch-screen with data logging and programmable settings
    • Multiple communication ports: Ethernet, USB, IEEE, RS232

     

  • ThermoSpot® Systems – Direct Contact Thermal Test Solutions

    Key Features:

    • Temperature range: -65°C to +175°C
    • Cooling power up to 120W at -40°C
    • Fast transition rate (<35 sec from +25°C to -40°C)
    • Reliable thermal cycling without thermoelectric modules
    • Flexible thermal probe with interchangeable ThermoBridge™
    • Touchscreen controller with programmable profiles
    • Connectivity options: Ethernet, USB, IEEE, RS232
    • Easy, secure connection to in-circuit or socketed DUTs

  • Key Features:

    • Single output up to 360W: Choose between 18V/20A or 35V/10A
    • Mixed-mode regulation for high accuracy and low noise
    • Fanless convection cooling for completely silent operation
    • Bench or rack mountable, front and rear terminals
    • OVP trip, high-resolution settings, and remote sense terminals
    • P models offer USB, RS232, LAN interfaces (GPIB optional)
    • Rotary, keypad, and step control for voltage and current
    • Non-volatile memory for storing up to 25 user presets
    • Seamless integration with Test Bridge software and automation systems

     

  • Compact yet powerful, the WA301 extends the output of your function generator with clean, reliable amplification up to 30V peak-to-peak.

    Key Features:

    • 30V peak-to-peak output swing
    • DC to 1MHz wide bandwidth
    • High impedance input with 0dB to +20dB variable gain
    • 50 Ohm and 600 Ohm outputs
    • Switchable 20dB output attenuator
    • Fully protected output for safe use
    • Ideal for extending function generator output capability

     

  • The new G5.RSS series features

    • High control dynamics
    • An exceptional accuracy
    • A nominal output voltage of up to 3000 VDC
    • A wide current-voltage range with an auto-ranging factor of 3.
    • You get the best value for your investment.

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Bidirectional (source & sink), Regenerative 0…65VDC to 0…1500VDC, 20kW up to 1.5 MW 

    • cell system nominal voltage and type of chemistry
    • number of cells
    • internal resistance and associated parameters
    • cell temperature progression
    • allowed current
    • charge efficiency
    • energy computing and management facilities
    • time-dependent and functional dependent parameters

     

    • Setting of operational parameters for each output phase: (frequency, phase, voltage, basic waveform)
    • Defining functional blocks enabling a wide variety of modulation capabilities
    • Defining, editing and storing of even complex and long test sequences
    • Preview window for output voltage waveforms
    • LC load mode, definition of complex equivalent circuits
    • Hand drawing curve tool and FOURIER tool (harmonics synthesis)
    • TC.ACS provides an extensive safety concept in order to detect unwanted or off-limit conditions very quickly and to initiate controlled limiting or even a shutdown.

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Photovoltaic applications, the quality and technical data of the AC-DC converter is of primary interest. Solar installations are intended for a lifetime of roughly 20 years, therefore even fractions of a percent in efficiency will represent significant amounts of energy losses.

  • Programmable Grid-tie Sink High-Power DC Supply,

  • Programmable Grid-tie Source & Sink Technology
    Wide range of power 20 to 512 kW, expandable up to several MW