1 800 665 7301 | info@tmetrix.com

  • with analogue and digital control, USB, RS232, LAN (LXI) and GPIB

    • Versatile solution for direct testing of dc power sources and PFCs
    • Constant current, resistance, conductance and power modes
    • Wide voltage and current range, 10 to 500V and 0 to 16A
    • 400 watts continuous dissipation at 28°C (360W at 40°C)
    • High resolution and accuracy for level setting
    • Built-in transient generator with variable slew
    • Current monitor output for waveform viewing
    • Variable drop-out voltage for battery testing
    • High resolution backlit graphic LCD with soft key control
    • Analogue remote control of levels and TTL control of on/off and transient switching
    • Front and rear input terminals
    • Load inputs rated to CAT II (300V)
    • Full bus control via USB, RS232, GPIB and LXI compliant LAN interfaces

     

    • Multiple ranges on each output for wider voltage/current choice
    • Four independent 105W full performance outputs
    • Instant individual on/off control plus sequencable multi on/off
    • Simultaneous display of meters and settings for all outputs
    • Up to 250 settings memories for individual or multiple outputs
    • Instant access to voltage/current setting for any output
    • USB, RS-232, LXI compliant LAN, and GPIB* interfaces (P versions)
    • USB, RS-232, LXI compliant LAN, and GPIB* interfaces (P versions)
      Duplicate power and sense terminals at rear (P versions)

     

    • Frequency up to 160MHz, 15 digits or 1µHz resolution
    • Wideband noise generator | high resolution pulse generator
    • Arbitrary waveforms up to 16bits at 800MS/s
    • Comprehensive internal/external digital and analog modulations
    • Two identical channels with phase control, coupling and tracking
    • USB and LXI compliant LAN interfaces, plus optional GPIB interface

     

  • Pulse and Universal Generator with 25 or 50MHz models, single or dual channel

    TGP3100 Series

     

    • Arbitrary waveforms at 800MS/s sampling rate and 16-bit vertical resolution
    • Extensive internal/external modulation of all waveform types
    • Linear and logarithmic sweeps of all waveform types
    • Front panel mounted USB Flash drive interface
    • GPIB (option), USB and LXI compliant LAN interfaces
    • Triggered (burst count) or gated operation using internal or external trigger sources

     

    • Arbitrary waveforms at 800MS/s sampling rate and 16-bit vertical resolution
    • Extensive internal/external modulation of all waveform types
    • Linear and logarithmic sweeps of all waveform types
    • Front panel mounted USB Flash drive interface
    • GPIB (option), USB and LXI compliant LAN interfaces
    • Triggered (burst count) or gated operation using internal or external trigger sources

     

    • Arbitrary waveforms at 800MS/s sampling rate and 16-bit vertical resolution
    • Extensive internal/external modulation of all waveform types
    • Linear and logarithmic sweeps of all waveform types
    • Front panel mounted USB Flash drive interface
    • GPIB (option), USB and LXI compliant LAN interfaces
    • Triggered (burst count) or gated operation using internal or external trigger sources

     

    • Arbitrary waveforms at 800MS/s sampling rate and 16-bit vertical resolution
    • Extensive internal/external modulation of all waveform types
    • Linear and logarithmic sweeps of all waveform types
    • Front panel mounted USB Flash drive interface
    • GPIB (option), USB and LXI compliant LAN interfaces
    • Triggered (burst count) or gated operation using internal or external trigger sources

     

    • Sine frequency up to 240MHz with 1µHz resolution
    • Up to 100MHz high resolution pulse generator
    • Arbitrary waveforms up to 16bits at 800MSa/s
    • Wideband noise generator

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Bidirectional (source & sink), Regenerative 0…65VDC to 0…1500VDC, 20kW up to 1.5 MW 

    • cell system nominal voltage and type of chemistry
    • number of cells
    • internal resistance and associated parameters
    • cell temperature progression
    • allowed current
    • charge efficiency
    • energy computing and management facilities
    • time-dependent and functional dependent parameters

     

    • Setting of operational parameters for each output phase: (frequency, phase, voltage, basic waveform)
    • Defining functional blocks enabling a wide variety of modulation capabilities
    • Defining, editing and storing of even complex and long test sequences
    • Preview window for output voltage waveforms
    • LC load mode, definition of complex equivalent circuits
    • Hand drawing curve tool and FOURIER tool (harmonics synthesis)
    • TC.ACS provides an extensive safety concept in order to detect unwanted or off-limit conditions very quickly and to initiate controlled limiting or even a shutdown.

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Positional current probe,  PCB track Touch & Measure

    Unique technology enabling current measurement in PCB tracks bandwidth of DC to 5MHz, dynamic range of 10mA to 20A pk-pk useable with any normal oscilloscope, safety rated to 300V Cat II,  investigates waveforms in any conductor including ground planes.

     

  • Photovoltaic applications, the quality and technical data of the AC-DC converter is of primary interest. Solar installations are intended for a lifetime of roughly 20 years, therefore even fractions of a percent in efficiency will represent significant amounts of energy losses.

  • Programmable Grid-tie Sink High-Power DC Supply,