1 800 665 7301 | info@tmetrix.com

  • High-Power AC/DC Load Simulator with PHIL Interface

    • Scalable Power Density: Available in 30kVA/kW, 45kVA/kW, and 55kVA/kW models, with parallel cabinets up to 550kVA/kW.
    • Versatile AC/DC Load Capability: Supports single-phase, split-phase, three-phase, and multi-channel configurations.
    • Dual Constant Power Voltage Ranges:
      • AC Voltage: 5-220V L-N / 9-380V L-L & 5-440V L-N / 9-760V L-L
      • DC Voltage: 0-335Vdc & 9-650Vdc
    • Advanced PHIL Interface (Option H): High-speed analog I/O for real-time frequency, voltage, and current control.
    • Regenerative Power Efficiency: Returns over 90% of absorbed energy back to the grid, reducing operational costs & heat dissipation.
    • Dynamic Load Simulation: Simulates harmonics, transient conditions, and waveform distortions for real-world power testing.
    • SmartSource Suite for Remote Control: Web-based monitoring and test automation via LAN, USB, GPIB, and RS232.

     

  • The AZX Series (Regenerative AC / DC Power Source) is a family of high power, single, split and three phase, AC, DC and AC+DC output capable Power Sources with full energy recovery to the AC mains when sinking power from the equipment under test. Available models range from 30 kVA to 440 kVA. Using a modern color touch screen based user interface for ease of use, the AZX Series is cost effective and fully programmable for both basic frequency conversion and advanced AC power line or DC power disturbance test applications requiring up to 1000 Hz fundamental frequency.

    The energy recovery capability allows both sourcing and sinking of current and power up to 100% of rated power. Adding the Load Option (Option L) adds full electronic regenerative AC & DC Load programming capability to the AZX.

     

    • 2U Chassis – 19″ rack mount 3.48” Height, 9.60” Depth and Weight 6lb.
    • Power 120V AC 60Hz
    • Washable front removable air filter
    • Ball Bearing AC fans provide 330 CFM
    • Dual plenum design
    • Cooling for 160mm,220mm depth modules
    • Diverts lower warmed air to rear of Cabinet
    • RM option diverts lower air to front of Cabinet

     

    • accommodate these control schemes
    • total control system interface on a single VME-standard card
    • occupies the left-most slot of the crate
    • monitoring voltage reference inputs, output voltages and fault conditions
    • standard VMEbus-compatible 6U by 220 mm board installed
    • Eurocard crate
    • Two 96-pin I/O connectors

     

    • provides precision bi-polar output currents
    • minimal zero-cross over distortion
    • 19” rack mounted 6U x 220 mm crate
    • crate has 17 slots; 16 (slot 0 thru 15)
    • connectors
      • J1 (ExtIntlk),
      • J2 (CrateOK),
      • J3 (Input Reference Voltages),
      • J4 (Output Monitors), and
      • J9 (Bitbus)