Description
•4 channels input (Not isolated) LOGIC PROBE
•For voltage/contact signal ON/OFF detection
•3 steps selectable of input threshold
•Response pulse width 500 ns or more
•Connection with a Memory HiCorder, miniature terminal type the 9320-01, large terminal type the 9320
9320 | For the Memory HiCorder, large terminal type |
---|---|
9320-01 | For the Memory HiCorder, miniature terminal type |
Note: Caution for terminal size connectiong to a Memory HiCorder
■ Basic specifications (Accuracy guaranteed for 1 year)Note: The unit-side plug of the 9320-01 is different from the 9320
Function | Detection of voltage signal or relay contact signal for High/Low state recording |
---|---|
Input | 4 channels (common ground between unit and channels), digital/contact input, switchable (contact input can detect open-collector signals) LOGIC PROBE Input resistance: 1 MΩ (with digital input, 0 to +5 V) 500 kΩ or more (with digital input, +5 to +50V) Pull-up resistance: 2 kΩ (contact input: internally pulled up to +5 V) |
Digital input threshold | 1.4V/ 2.5V/ 4.0V |
Contact input detection resistance | 1.4 V: 1.5 kΩ or higher (open) and 500 Ω or lower (short) 2.5 V: 3.5 kΩ or higher (open) and 1.5 kΩ or lower (short) 4.0 V: 25 kΩ or higher (open) and 8 kΩ or lower (short) |
Response pulse width | 500 ns or more |
Max. allowable input | 0 to +50V DC (the maximum voltage that can be applied across input pins without damage) |
Dimensions and mass | 62 mm (2.44 in)W × 94 mm (3.70 in)H × 20 mm (0.79 in)D, 150 g (5.3 oz), Main unit cable 1.5 m (4.92 ft), input section cable 300 mm (0.98 ft) |
Accessories | IC clip leads ×1, Alligator clip leads ×1, Carrying case ×1, Instruction Manual ×1 |