FormFactor Beaverton Inc

Showing 17–32 of 69 results


    • Functional temperature range of -263 to +150°C
    • Stainless steel tip material for thermal decoupling
    • Coaxial cable with TCE matched inner and outer conductors
    • Consistent tip geometry even at cryogenic temperatures

     

  • High-performance DC Parametric Probe

    • Ultra-low, fA-level current and fF-level capacitance measurements from -65 °C to + 300 °C
    • Guarantees fully-guarded measurements to fA and fF levels
    • Individual connectors provide force-sense connection for quasi-Kelvin and CV measurements
    • Allows probing of different pad materials and sizes
    • Fast replacement of worn probes without the need for tools

     

  • Multi-contact DC Probe with flat tip needles

    • Power bypass inductance: 8 nH
    • Standard DCQ probes have flat tip needles available in nickel-plated tungsten or BeCu with diameters of 0.75 mil, 1.0 mil and 1.5 mil.
    • Supports collinear and non-standard needle configurations
    • Up to 16 DC for standard; maximum of 24 DC for custom
    • Ideal for probing the entire circuit for functional test
    • DC probes can provide power or slow logic to circuit under test

     

  • Tables from simple to highly sensitive

    • Designed for use with specific Probe Systems
    • Tables to suit all facility requirements and applications
    • Stable probing, even in submicron range
    • Granite platen ensures rigidity and temperature stability
    • Can be combined with the Shield Enclosures

     

  • Multi-contact DC Probe with full-radius needles

    • Full-radius, nickel-plated tungsten needles
    • Power bypass inductance: 16 nH
    • Supports collinear and non-standard needle configurations
    • Support up to a maximum of 12 ceramic blades DC needles / contacts
    • Ideal for probing the entire circuit for functional test
    • DC probes can provide power or slow logic to circuit under test

     

  • Rugged, deep reach RF probing for modules and circuit boards

    • DC-40 GHz bandwidth
    • 10 ps rise time
    • Low insertion and return loss
    • 2 mils of tip-to-tip compliance
    • High probing angle and clearance

     

  • Perfectly matched to the |Z| Probe®

    The CSR family of calibration substrates delivers the highest accuracy available due to the high quality of each substrate. The calibration standards are manufactured using rugged, hard gold, which ensures a long lifetime.

     

     

    • SlimVue Microscope
      • Combined eye-pieces and CCD camera mount
      • 3x zoom and quick lens exchange
      • Quick lens exchange
      • 1 um optical resolution
      • Minimized scope footprin
    • Application Specific Sigma Kits
      • Optical feedback on platen position (gauge)
      • Adaptable to any mmW/sub-THz applications
      • Seamless integration with any mmW modules and tuners
      • Fast mounting and setup change
    • THz measurement capability
      • Rock-solid mechanical design
      • Submicron stage accuracy
      • Optical feedback on platen and probe position (gauge)
      • Motorized positioner

     

  • Durable multi-contact wafer probe with controlled impedance power bypass technology

    • High performance power bypassing provides low-impedance and resonant-free connections to 20 GHz
    • RF bandwidth to 500 MHz
    • Long probe life: > 250,000 contacts
    • Beryllium-copper tips for gold pads or tungsten for aluminum pads
    • Oscillation-free testing of wide-bandwidth analog circuits
    • Use with ACP series probes to provide functional at-speed testing for known-good-die
    • Mix multiple contact types: Ground, Power (Standard or Eye-Pass), Logic/Signal
    • Low and repeatable contact resistance on aluminum pads ( < 0.25 Ω on Al, < 0.01 Ω on Au)

     

    • Three Probe Technologies
      • nfinity Probe: best for Al (Si)
      • ACP Probe: best for AU (III-Vs)
      • |Z| Probe: robust solution (long lifetime)
    • Precise Contact Solution
      •  Precision probe alignment
      • Consistent contact force and overtravel
      • Stable contact performance
    • WinCal XE Calibration Software
      • Exclusive 1-, 2-, 3-, and 4-port on-wafer calibration algorithms
      • Automated calibration monitoring
      • Unique measurement & analysis methods

     

  • Multiline TRL Substrates for T-Wave Probes

    • Substrate material: High-resistivity silicon
    • Substrate thickness: 275 µm
    • Dielectric constant: 11.8
    • Nominal Z0: 50 Ω

     

  • 200 mm semi-/ fully-automated production probe system

    • Up to 20 dies/sec (70,000 dies/hour) with MultiDie Testing technology
    • Faster time to data
    • Highest Z-axis resolution of any production prober
    • Highest Z-axis resolution of any production prober
    • Interfaces to all major analysis instrumentation, optics software and testers
    • Backside instrumentation, e.g.: Integrating Sphere, Fiber setup, Pressure Module
    • Highly accurate light measurement

     

     

  • Long-lasting, rugged RF and microwave on-wafer probes

    • Unique Air Coplanar tip design with choice of beryllium copper (BeCu) or tungsten tip material
    • DC to 110 GHz models available in single and dual line versions
    • Low insertion and return loss with ultra-low-loss ( -L ) versions
    • Excellent crosstalk characteristics
    • Wide operating temperature -65 ° C to + 200 ° C
    • Wide range of pitches available, from 50 to 1250 µm
    • Individually supported contacts
    • Reduced contact (RC) probe tips for small pads
    • BeCu tip provides rugged, repeatable contact on gold pads

     

    • Flexibility
      • Different substrate carriers for wafers up to 200 mm or single dies
      • Probe cards and/or up to eight positioners
      • Use with liquid nitrogen or helium, depending on the target temperature
    • Stability
      • Probe positioners placed inside vacuum chamber
      • Short and stable probe arms
      • Solid station frame with built-in vibration-isolation
      • Optional microscope bridge
      • Precise probe positioning
    • Ease of Use
      • Joystick controller
      • Manual probe positioners with rotary feed-throughs
      • Front loading capability through load door
      • Comfortable and easy operation

     

    • Flexibility
      • Different substrate carriers for wafers up to 200 mm or single dies
      • Probe cards and/or up to eight positioners
      • Optional thermal chuck (-60°C to 300°C) and pressure regulation
    • Stability
      • Probe positioners placed inside vacuum chamber
      • Short and stable probe arms
      • Solid station frame with built-in vibration-isolation
      • Optional microscope bridge
      • Precise probe positioning
    • Ease of Use
      • Joystick controller
      • Manual probe positioners with rotary feed-throughs
      • Front loading capability through load door
    • High measurement throughput
      • Software control of chuck for fast step-and-repeat testing of the entire wafer
      • Fast step-and-repeat testing of the whole wafer

     

    • Flexibility
      • Different substrate carriers for wafers up to 200 mm or single dies
      • Probe cards and/or up to eight positioners
      • Optional thermal chuck (-60°C to 300°C) and pressure regulation
    • Stability
      • Probe positioners placed inside vacuum chamber
      • Short and stable probe arms
      • Solid station frame with built-in vibration-isolation
      • Optional microscope bridge
      • Precise probe positioning
    • Ease of Use
      • Joystick controller
      • Manual probe positioners with rotary feed-throughs
      • Front loading capability through load door
      • Comfortable and easy operation
    • High measurement throughput
      • Software control of chuck for fast step-and-repeat testing of the entire wafer
      • Fast step-and-repeat testing of the whole wafer

     