1 800 665 7301 | info@tmetrix.com

Uncategorized

Showing 113–128 of 264 results


  • Excellent Performance – Longest Lifetime

    • Best price per contact – typically over one million (1,000,000) touchdowns
    • RF/Microwave signal is shielded and completely air isolated in the probe body
    • Excellent performance in vacuum environments and temperatures as low as 4 K, or as high as 300°C
    • Highest impedance control with perfectly-symmetrical, MEMS-machined coplanar contact structure
    • Probe on any pad material with minimal damage

     

    • Highest accuracy in test results
    • Easy setup even for less experienced users
    • Minimized coupling losses with minimal trench dimensions
    • Exclusive FormFactor-developed automated test methodology
    • Wide range of tools for capturing, logging and interpreting data
    • Enables hands-free autonomous calibration and re-calibration at multiple temperatures
    • Search First Light feature enables automated determination of initial position for optimization
    • Once aligned, all calibration functions are automated and performed through SiPh-Tool

     

    • Super high precision, ±0.05% amplitude accuracy, ±0.2° phase accuracy
    • Wide-bandwidth DC to 500kHz excellent frequency characteristics
    • Applications in the fields of electric and hybrid electric vehicles
    • Wide operating temperature range(-30 ℃ to 85 ℃) fit for automobile applications
    • deal for evaluation of solar power generation and fuel cells to measure battery charge and discharge and the secondary side of inverters
    • For observing waveforms to be used with the oscilloscopes or Memory HiCorders (use with SENSOR UNIT)

     

    • Online Battery Testing – Diagnose batteries while in operation without system shutdown.
    • Rapid Results – Get resistance and voltage readings in as fast as 2 seconds.
    • Intelligent Diagnostics – Auto-assesses battery status: PASS, WARNING, or FAIL.
    • Noise-Resistant Design – Proprietary technology ensures stable readings, even near UPS inverters.
    • Wireless Integration – Transfer and organize data on your mobile device using GENNECT Cross.
    • Measurement Navigator – Screen and audio guidance helps streamline testing workflows.
    • Large Data Capacity – Save up to 6,000 measurement records linked to customizable site profiles.
    • Ergonomic Design – Improved grip and field durability with a new protective cover.

     

    Select options This product has multiple variants. The options may be chosen on the product page
  • Easy Pole Clamp-On Ground Resistance Tester with Super Slim Jaw

    • Earth resistance measurement for multi-grounded systems
    •  Measure leak current with absolute certainty with highly sensitive 0.01 mA resolution (at 20.00 mA range)
    • Measure load current up to 60.0 A range
    • Clamp at the narrowest point

     

    • Cord is insulated
    • BNC connectors at both ends,
    • 1.6 m (5.25 ft) length

     

  • Simple Circuit Analysis & Detailed Acceptance/Rejection Decision-Making Firmware Upgrade for the IM3570

    • Automatically select the equivalent circuit model from the five typical models to minimize the differences between the measured values and the ideal frequency characteristics derived from the analysis results
    • Determine acceptance/rejection for the L, C, and R elements comprising a part and the resonance sharpness (mechanical quality coefficient)
    • Make detailed decisions on the elements using the resonance of a piezoelectric element or inductor

     

    • LCR measurement, DCR measurement, sweep measurement, continuous measurement and high-speed testing achieved with one instrument
    • High-speed testing, achieving maximum speeds of 1.5ms (1 kHz) and 0.5ms (100kHz) in LCR mode
    • High-accuracy measurements, basic accuracy of Z parameter: ± 0.08%
    • Perfect impedance analyzer for testing the resonance characteristics of piezoelectric elements, C-D and low ESR measurement of functional polymer capacitors, DCR and L-Q measurement of inductors (coils and transformers)
    • Perform frequency sweeps, level sweeps, and time interval measurements in analyzer mode

     

  • 3-Channel AC/DC Power Meter for Single-Phase to 3P4W Equipment such as Motors, Inverters, Power Conditioners, and Power Supplies

    • Voltage/current/power basic accuracy of ±0.1% *
    • Direct input up to 1000 V AC/DC / 65 A
    • Harmonic measurement as standard feature, IEC61000-4-7 compliant
    • Little instrument loss, even with large currents. DCCT input with an input resistance of 1 mΩ or less.
    • Power factor effect of ±0.1% f.s. delivers highly accurate measurements even for no-load testing of transformers with a low power factor
    • Measurement of multiple connections in the optimal range for each due to independent ranges for each channel
    • Measure up to 5000 A AC with optional current sensor

     

    • Compatible with the SPECpower® benchmark for server power consumption SPECpower® is a registered trademark of Standard Performance Evaluation Corporation
    • Measure DC, and single-phase 2-wire to 3-phase 4-wire with 3-channel input
    • For development and production of motors, inverters, power conditioners, power supplies, and other devices
    • High-precision basic accuracy of ±0.1 % (*1) (*1) For complete details, please refer to the specifications
    • Wide frequency bandwidth of 0.1 Hz to 100 kHz or DC
    • High-current measurement up to 65 A of direct input
    • Harmonic measurement up to the 50th order according to IEC 61000-4-7
    • High-accuracy measurement, even with a low power factor for no-load testing of transformers and motors
    • Built-in external sensor input terminals to measure up to 5000 A AC
    • Synchronize up to 8 units for multi-unit measurement
    • Create a 6-channel power meter by synchronizing two PW3337 units and using the free PC application

     

    • Power supply for high-precision current sensors with waveform output / RMS output functionality
    • Output Terminal BNC Terminal
    • Output voltage Waveform output: 2 V f.s. / RMS output: 2 V DC f.s.
    • Operating temperature range -10 °C to 50 °C (14 °F to 122 °F)
    • Power supply AC Adapter Z1008 (100 to 240 V AC, 50/60 Hz, maximum rated power when used with sensors: 45 VA)
      External power supply (10 to 30 V DC; maximum rated power: 15 VA)

     

  • The new G5.RSS series features

    • High control dynamics
    • An exceptional accuracy
    • A nominal output voltage of up to 3000 VDC
    • A wide current-voltage range with an auto-ranging factor of 3.
    • You get the best value for your investment.

     

    • High Power Density 3.3kW in 2U
    • Wide Range of popular worldwide AC inputs, 1ø (230VAC) & 3ø (208VAC, 400VAC)
    • Active Power Factor Correction (Single-Phase & Three-Phase AC Input)
    • Output Voltage up to 600V, Current up to 400A
    • Built-in RS-232/RS-485 Interface Standard
    • Global Commands for Serial RS-232/RS-485 Interface
    • Auto-Re-Start / Safe-Start: user selectable
    • Last-Setting Memory
    • High Resolution 16 bit ADCs & DACs
    • Low Ripple & Noise
    • Front Panel Lock selectable from Front Panel or Software
    • Reliable Encoders for Voltage and Current Adjustment
    • Constant Voltage/Constant Current auto-crossover
    • Parallel Operation with Active Current Sharing; up to four identical units.
    • Advanced Parallel Master / Slave. Total Current is Programmed and Measured via the Master.
    • Independent Remote ON/OFF and Remote Enable/Disable

     

     

    • High Power Density 750W in 1U full-rack size
    • Wide Range Input (85 – 265Vac Continuous)
    • Active Power Factor Correction (0.99 typical)
    • Output Voltage up to 600V, Current up to 100A
    • Built-in RS-232/RS-485 Interface Standard
    • Last Setting Memory; Front Panel Lockout
    • Advanced Parallel reports total current up to four identical units

     

    • Wide Range Input (85 – 265Vac Continuous)
    • Active Power Factor Correction (0.99 typical)
    • Output Voltage up to 600V, Current up to 100A
    • Built-in RS-232/RS-485 Interface Standard
    • Last Setting Memory; Front Panel Lockout
    • Advanced Parallel reports total current up to four identical units

     

    • Dual inputs allows Differential or Phaseto-Phase voltage measurement
    • High speed DSP provides up to 60 filtered readings per second
    • True RMS AC measurement from 0.01Hz to 600Hz—covering VLF to aviation frequencies
    • AC noise rejection 78dB—for rock solid, six digit DC Measurements
    • Optional battery pack goes up to 11 hours between charges
    • G Series—high input impedance probes for electrostatic applications
    • CE mark Certified to EN61010
    • Available ISO 17025 accredited calibration
    • Three year extended warranty (one year standard warranty)

     


Showing 113–128 of 264 results

Filters

 

Suppliers

Latest News