  • The EME Guard Plus is a lightweight and robust personal protection monitor designed to ensure the safety of workers operating near electromagnetic field (EMF) emitters such as antennas, radars, and base stations. With a frequency range of 1 MHz to 40 GHz, this device continuously monitors and records EMF exposure levels while providing immediate audio, visual, and vibrating alerts when exposure exceeds predefined safety thresholds. Customizable alarm settings and a triaxial isotropic probe ensure accurate and reliable measurements.

     

  • The EME Guard XS Radar is a state-of-the-art RF safety monitor, specifically designed for workers operating near radar transmitters and antennas. With its isotropic tri-axis E-field sensors, this compact device provides continuous EMF monitoring over a frequency range of 1 MHz to 40 GHz, including short pulsed signal detection. Equipped with audio and visual alarms, it alerts users instantly when EMF exposure exceeds predefined safety thresholds, creating a safer working environment for military, aviation, and telecom personnel.

     

  • The EMI 64k software allows to embed the TDEMI systems in a fully automated test environment.

    • Full automation of EMI testing according to all commercial and military standards
    • Automated control of turntable, antenna and other equipment
    • Height and Angular Scan
    • Procedures according to standards as well as customized procedures
    • Reducing the cost for EMC and communication testing and certification by tailored packages

     

  • The measurement system for all emission measurments in the frequency range 1 Hz – 44 GHz.

    • Frequency Range  1 Hz – 30MHz, 1GHz, 3GHz, 6GHz, 9GHz, 18GHz, 26GHz, 40 GHz and 44GHz
    • 225 MHz Real-time Analysis Bandwidth
    • Weighted Real-time Spectrogram up to 44 GHz
    • CISPR Bandwidths 200 Hz, 9 kHz, 120 kHz, 1 MHz
    • MIL/DO Bandwidths 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz

     

  • The measurement system for all emission measurments in the frequency range 1 Hz – 44 GHz.

    • Full compliance EMI Reciever according to standard CISPR 16-1· 1, ANSI C63.2, MIL->461, and DO·160
    • Spectrum Analyzer
    • Integrated LOW Noise Ampllfier (lNAI)
    • Integrated Preselect1on
    • Tradttional and FFT·based Mode
    • Automatic Stepped Attenuator
    • Ultra Low Noise Floor
    • Excellent spurious Performance
    • Real-time Spectrum Analyzer optional
    • Vast IQ-Bandwidth

     

  • TDEMI Mobile+. The ultra mobile EMI receiver – Emission measurements everytime, everywhere. Fully stand-alone operable.

    • Frequency Ranges 10Hz – 1GHz, 3GHz, 6GHz or 7GHz
    • 16000x faster than conventional receivers
    • Super compact design and 12V supply
    • 225 MHz fully gapless real-time analysis bandwidth
    • Weighted Real-time Spectrogram

     

  • Ultra High Performance RT Spectrum Analyzer. Ultrafast EMI Measurements.

    • Frequency Range from 1 Hz up to 50 GHz
    • 225 MHz Real-time analysis bandwidth
    • 100 dB Dynamic Range
    • Ultrahigh performance preselection in all modes
    • Up to 510 MHz Real-time IQ-Analysis bandwidth
    • Ultra High Performance Spectrum Analyzer

     

     

    • Compact, air-cooled OEM style
    • Superior pulse repeatability
    • Simple parallel operation for higher power
    • Optional Active PFC (pf = 0.98)
    • Full remote control interface
    • High EMI-RFI immunity

     

    • Advanced semiconductor technology
    • High-quality construction
    • Rapid capacitor and pulse-forming network charging
    • Compact and lightweight design
    • Simple parallel operation for higher power needs
    • Compatible with worldwide input voltages and frequencies
    • Fully adjustable output voltage
    • Comprehensive remote control interface

     

  • High-Speed Current Control: No dynamic overshoot or oscillation
    High Slew-Rate: Up to 30A/*s for fast load changes
    Low Voltage Operation: Stable operation with no turn-on delay
    Multi-Functional: Seven load modes and four operating modes
    Parallel Operation: Up to 10kW with 10 units
    User-Friendly Interface: Built-in USB and optional IEEE interfaces
    Compliance: EN61010-1 compliant with a two-year warranty

    • 3GHz RF analog signal generator
    • AM, FM, PM, Sweep & Pulse Modulation
    • Exceptionally Low Phase Noise of -145dBc/Hz @100MHz and 10@kHz offset
    • Field ready, with 10” touch screen suited for day and night use and 2 hour battery operation
    • Remotely programmable via MATLAB, Python, LabVIEW and other software programming environments.
    • Removable uSD card for instrument security

     

    • 20 Amp Operation: Full performance with 20 amp service
    • Automatic Power Reduction: Reduces power usage during idle periods
    • Heat Only Mode: Reduces power usage when cold temperatures are not used
    • WhisperStream Technology: quieter, smooth-sounding operation, 56 dBA
    • Frost Free Test Environment: dry air purge for tester interface, prevents condensation:
      0.5 to 3scfm (0.25 to 1.5 l/s)
    • Heated Defrost: quickly removes moisture buildup from internal chiller
    • DUT Temperature Control : Proprietary control algorithm enables DUT temperature to be directly controlled
    • Transition Rate*
      -55 to +125°C, approx. 10 seconds
      125 to -55°C, approx. 10 seconds
    • System Airflow Output*
      4 to 18scfm (1.9 to 8.5 l/s) Continuous
    • Temperature Range*
      -80 to +225°C (60Hz) No LN2 or LCO2 Required

     

    • High reliability thermal cycling without thermoelectric modules
    • Temperature range: -65 to 175°C
    • Cooling power:
      • 40W at -40°C for lower power devices
      • 55W at -55°C and 120W at -40°C.
    • Transition rate: up to <35 sec over 25 to -40°C
    • Easy and secure thermal connection to in-circuit or test socked DUT
    • Touch-screen controller: user-programmable temperatures, graphing, data logging
    • Communications options: Ethernet, USB, IEEE, RS232

     

  • -60° to +200°C

    • Economy model with high thermal capacity
    • Precise temperatures with fast transitions from -60 to 200°C
    • No annual leak testing required per EU 517/2014 F-Gas Regulation
    • Effective testing and conditioning of electronic components, boards, and modules
    • Available for 50 and 60Hz operation
    • No need for Liquid Nitrogen (LN2) or Liquid Carbon Dioxide (LCO2)
    • Remote communications and set up and touch screen operation
    • User Defined Temperature Limits

     

     

    • High voltage output to 300Vp-p (±150V)
    • Output current to 150 mA
    • Full power bandwidth from DC to >500kHz
    • Slew rate to 200V/µs
    • Low distortion
    • Low cost
    • Custom Configuration of gain and signal Ground

     

    • Single channel
    • High voltage output to 400Vp-p (±200V)
    • Output current to 125 mA
    • Full power bandwidth from DC to >500kHz
    • Slew rate to 400V/µs
    • Monitor Output
    • Precise signal amplification for multiple applications
    • Compatible with any of the Tabor waveform generators

     