    • Available in 4.5-digit (60,000 count) and 6.5-digit (2,200,000 count) resolutions.
    • Wide measurement range:
      • DC Voltage: Up to 1000V
      • AC Voltage: Up to 750V (True RMS)
      • Current: 10A (AC/DC)
      • Resistance: 100MΩ (2-wire/4-wire)
      • Capacitance: 2nF – 100mF
      • Temperature measurements with TC and RTD sensor support.
    • High-speed measurements:
      • T3DMM4-5: 150 readings per second
      • T3DMM6-5: 10,000 readings per second
    • Advanced mathematical functions such as Max, Min, Standard Deviation, dBm/dB, Relative Measurement, Pass/Fail Analysis, and Histograms.
    • Connectivity: USB Device, USB Host, and LAN for remote operation via SCPI commands.
    • Data Storage: 1GB NAND flash memory for saving configuration files and test data.
    • Built-in cold junction compensation for accurate temperature measurements.
    • File management system supporting U-disc and local storage for convenient data access.
    • Comprehensive user interface with a dual-display system for easy navigation.
    • Automatic measurement functions, including statistical analysis, gating, and reference functions.

     

    • 20 Amp Operation: Full performance with 20 amp service
    • Automatic Power Reduction: Reduces power usage during idle periods
    • Heat Only Mode: Reduces power usage when cold temperatures are not used
    • WhisperStream Technology: quieter, smooth-sounding operation, 56 dBA
    • Frost Free Test Environment: dry air purge for tester interface, prevents condensation:
      0.5 to 3scfm (0.25 to 1.5 l/s)
    • Heated Defrost: quickly removes moisture buildup from internal chiller
    • DUT Temperature Control : Proprietary control algorithm enables DUT temperature to be directly controlled
    • Transition Rate*
      -55 to +125°C, approx. 10 seconds
      125 to -55°C, approx. 10 seconds
    • System Airflow Output*
      4 to 18scfm (1.9 to 8.5 l/s) Continuous
    • Temperature Range*
      -80 to +225°C (60Hz) No LN2 or LCO2 Required

     

    • High reliability thermal cycling without thermoelectric modules
    • Temperature range: -65 to 175°C
    • Cooling power:
      • 40W at -40°C for lower power devices
      • 55W at -55°C and 120W at -40°C.
    • Transition rate: up to <35 sec over 25 to -40°C
    • Easy and secure thermal connection to in-circuit or test socked DUT
    • Touch-screen controller: user-programmable temperatures, graphing, data logging
    • Communications options: Ethernet, USB, IEEE, RS232

     

  • -60° to +200°C

    • Economy model with high thermal capacity
    • Precise temperatures with fast transitions from -60 to 200°C
    • No annual leak testing required per EU 517/2014 F-Gas Regulation
    • Effective testing and conditioning of electronic components, boards, and modules
    • Available for 50 and 60Hz operation
    • No need for Liquid Nitrogen (LN2) or Liquid Carbon Dioxide (LCO2)
    • Remote communications and set up and touch screen operation
    • User Defined Temperature Limits

     

     

  • High‐Resolution Portable TDR with Frequency‐Domain Analysis Tools

    Ideal for testing all types of microwave/RF and digital cables and connectors

    • Rugged portable TDR with S‐parameter tools
    • Resolves connector detail (<1 cm)
    • 75 μm (0.003 in.) cursor resolution
    • 16‐bit digital sampling at up to 250 KSPS
    • Stores thousands of TDR traces
    • USB host/client, 10/100 Ethernet
    • Lightweight, bright color screen
    • Internet streaming and remote control

     

  • Simplify Aging Aircraft Wiring Maintenance Using High-Resolution MOHR CT100 Series TDR Cable Analyzers

    • Designed for use with the high-resolution CT100 TDR Cable Tester
    • Ideal for TDR testing MIL-STD-1553B data bus aerospace cable assemblies
    • Detect and localize open, short, and partial cable and connector faults on the main bus and stubs
    • Detects cable and connector faults through 3+ transformer couplers
    • Simplifies troubleshooting of aging aircraft MIL-STD-1553 cable assemblies

     

  • Phase -Models Kitted for installation into End User’s Cabinet  and Phase -Models including Cabinet and Emergency Power off  (EPO)1

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 60,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 166.7 / 83.3 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 527/240 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 125.0 / 62.5  (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 466/212 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 25.0/13.9 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 15 (U) and Weight 320/146(LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power 15000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 41.7 / 21.0 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power 15000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 41.7 / 21.0 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power  12000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS  33.3/16.7 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power  9000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 0/13.9 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power  9000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 25.0/13.9 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     

  • The AFX Series is a family of high power, single, split and three phase, AC, DC and AC+DC output capable Power Sources. Available models range from 9 kVA to 60 kVA. Using a modern user interface for ease of use, the AFX Series is cost effective and fully programmable for both basic frequency conversion and advanced AC power line or DC Download the Brochurepower disturbance test applications.

     