1 800 665 7301 | info@tmetrix.com

Uncategorized

Showing all 15 results


  • The EME Guard Plus is a lightweight and robust personal protection monitor designed to ensure the safety of workers operating near electromagnetic field (EMF) emitters such as antennas, radars, and base stations. With a frequency range of 1 MHz to 40 GHz, this device continuously monitors and records EMF exposure levels while providing immediate audio, visual, and vibrating alerts when exposure exceeds predefined safety thresholds. Customizable alarm settings and a triaxial isotropic probe ensure accurate and reliable measurements.

     

  • The EME Guard XS Radar is a state-of-the-art RF safety monitor, specifically designed for workers operating near radar transmitters and antennas. With its isotropic tri-axis E-field sensors, this compact device provides continuous EMF monitoring over a frequency range of 1 MHz to 40 GHz, including short pulsed signal detection. Equipped with audio and visual alarms, it alerts users instantly when EMF exposure exceeds predefined safety thresholds, creating a safer working environment for military, aviation, and telecom personnel.

     

  • High‐Resolution Portable TDR with Frequency‐Domain Analysis Tools

    Ideal for testing all types of microwave/RF and digital cables and connectors

    • Rugged portable TDR with S‐parameter tools
    • Resolves connector detail (<1 cm)
    • 75 μm (0.003 in.) cursor resolution
    • 16‐bit digital sampling at up to 250 KSPS
    • Stores thousands of TDR traces
    • USB host/client, 10/100 Ethernet
    • Lightweight, bright color screen
    • Internet streaming and remote control

     

  • Simplify Aging Aircraft Wiring Maintenance Using High-Resolution MOHR CT100 Series TDR Cable Analyzers

    • Designed for use with the high-resolution CT100 TDR Cable Tester
    • Ideal for TDR testing MIL-STD-1553B data bus aerospace cable assemblies
    • Detect and localize open, short, and partial cable and connector faults on the main bus and stubs
    • Detects cable and connector faults through 3+ transformer couplers
    • Simplifies troubleshooting of aging aircraft MIL-STD-1553 cable assemblies

     

  • Phase -Models Kitted for installation into End User’s Cabinet  and Phase -Models including Cabinet and Emergency Power off  (EPO)1

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 60,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 166.7 / 83.3 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 527/240 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 125.0 / 62.5  (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 466/212 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 25.0/13.9 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 15 (U) and Weight 320/146(LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power 15000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 41.7 / 21.0 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power 15000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 41.7 / 21.0 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power  12000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS  33.3/16.7 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power  9000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 0/13.9 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power  9000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 25.0/13.9 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     

  • The AFX Series is a family of high power, single, split and three phase, AC, DC and AC+DC output capable Power Sources. Available models range from 9 kVA to 60 kVA. Using a modern user interface for ease of use, the AFX Series is cost effective and fully programmable for both basic frequency conversion and advanced AC power line or DC Download the Brochurepower disturbance test applications.

     

  • Next-gen Time-Domain Reflectometers replace the Tektronix® 1502C

    The new CT100 and CT100HF are the industry’s highest-resolution portable metallic TDRs, designed for testing all coaxial and twisted-pair cables and interconnects used in modern microwave/RF and digital systems. These are the only portable instruments that exceed all TDR specifications of the Tektronix® 1502C Metallic TDR Cable Tester, while providing next-generation improvements in TDR analysis, data storage, connectivity, and ergonomics.

    CT100 Series TDRs feature 8-10x sharper spatial resolution and100-1000x better Distance-to-Fault (DTF) resolution than competing TDR instruments, and have multi-GHz bandwidth similar to competing FDR (Frequency-Domain Reflectometer) instruments with similar or better cable fault sensitivity andorders-of-magnitude better DTF precision.

    These instruments’ unique combination of fast system rise-time,high-resolution time-base, and precision 16-bit impedance measurements allow you to identify and correct subtle changes in cable and connector performance before system failure. Some of the CT100 Series’ innovative features are described below. Also, please read CT100 Series Features for more information.

     


Showing all 15 results