LCR Meters | Impedance Analyzers | Capacitance Meters



Description

Impedance Analyzers, 1.3 GHz

IMPEDANCE ANALYZER   IM7580A

1MHz to 300MHz Measurement Frequency Impedance Analyzer with 0.5ms Test Speed and Superior Repeatability

• |Z|, L, C, R testing • Testing source frequency: 1 MHz to 300 MHz • Measuring time: 0.5 ms • Measure LCR and conduct frequency sweeps simultaneously

IMPEDANCE ANALYZER   IM7581

100kHz to 300MHz Measurement Frequency Impedance Analyzer with 0.5ms Test Speed

• |Z|, L, C, R testing • Testing source frequency: 100 kHz to 300 MHz • Measuring time: 0.5 ms • Measured value variability : 0.07% • Measure LCR and conduct frequency sweeps simultaneously
 

IMPEDANCE ANALYZER   IM7585

1MHz to 1.3GHz Measurement Frequency, 0.5ms Test Speed, and 0.07% Variability

• |Z|, L, C, R testing • Testing source frequency: 1 MHz to 1.3 GHz • Measuring time: 0.5 ms • Measured value variability : 0.07% • Measure LCR and conduct frequency sweeps simultaneously
 

IMPEDANCE ANALYZER   IM7583

1MHz to 600MHz Measurement Frequency and 0.5ms Test Speed

• |Z|, L, C, R testing • Testing source frequency: 1 MHz to 600 MHz • Measuring time: 0.5 ms • Measure LCR and conduct frequency sweeps simultaneously

SMD TEST FIXTURE   IM9100

High-precision four-terminal measurement for ultra small size 01005 (EIA)

• Direct connection type • SMDs with electrodes on the bottom • DC to 8MHz • Measurable sample sizes: 01005 to 0402 (EIA)

CHEMICAL IMPEDANCE ANALYZER   IM3590

Wide band 1mHz to 200kHz Chemical Impedance Analyzer for Testing Electrochemical Components and Materials, Batteries, and EDLC

• |Z|, L, C, R, σ, ε testing • Battery measurement • 1 mHz to 200 kHz • 2 ms measurement time

EQUIVALENT CIRCUIT ANALYSIS FIRMWARE   IM9000

Firmware Upgrade for the IM3570 Impedance Analyzer to Enable Cole-Cole Plots, Simple Circuit Analysis and Detailed Acceptance/Rejection Decisions

• Optional software for Model IM3570 • 5 equivalent circuit models • Plot frequency characteristics graph from analysis results • Cole-Cole plot, admittance circle display

IMPEDANCE ANALYZER   IM3570

Wide band 4Hz to 5Mz Impedance Analyzer for High Speed Testing and Frequency Sweeping of Piezoelectric Elements, Functional Polymer Capacitors, Coils and Transformers

 

• |Z|, L, C, R testing • 4 Hz to 5 MHz • 0.5 ms measurement time • Measure LCR and conduct frequency sweeps simultaneously
 

 

LCR Meters, 200 kHz to 8 MHz

LCR METER   IM3536

The New Standard for General-Purpose LCR Meters with Measurement Frequency from DC, 4Hz to 8MHz

• |Z|, L, C, R testing • Testing source frequency: DC, or 4 Hz to 8 MHz • Measuring time: 1 ms • Accuracy guaranteed range from 1mΩ • Continous testing under varying conditions

LCR METER   IM3523

Wide band 40Hz to 200kHz LCR Meter for High Speed Automated Testing on Production Lines

• |Z|, L, C, R testing • 40 Hz to 200 kHz • 2 ms measurement time

LCR METER   IM3533, IM3533-01

Wide band 1mHz to 200kHz LCR Meter for R&D Applications to Windings, Coil and Transformer Manufacturing

• |Z|, L, C, R testing • 1 mHz to 200 kHz • 2 ms measurement time • Transformer mode • Frequency sweep w/IM3533-01
 

 

 LCR Meters | Capacitance Meters, 1 kHz, 120 Hz

C METER   3506-10

Dual-band 1kHz/1MHz Capacitance Meter for High Speed Testing of Ceramic Capacitors on Production Lines

• C, D (tan δ), Q, and low capacitance testing • 1 kHz, 1 MHz • 1.5 ms measurement time at 1 MHz

C HiTESTER   3504

Dual-band 120Hz/1kHz Capacitance Meter for High Speed Inspection of Multi-Layer Ceramic Capacitors (MLCC) on Taping Machines

• C, D (tan δ), high capacitance MLCC testing • 120Hz or 1kHz • 2 ms measurement time

LCR HiTESTER   3511-50

Compact, dual-band 120Hz/1kHz LCR Meter for Integration into Automated Production Lines

• |Z|, L, C, R testing • 120Hz or 1kHz • 5 ms measurement time

 

 

Get in touch with us to inquire about our tailored consulting services.