Description
Impedance Analyzers, 1.3 GHz
 |
IMPEDANCE ANALYZER IM7580A
1MHz to 300MHz Measurement Frequency Impedance Analyzer with 0.5ms Test Speed and Superior Repeatability

• |Z|, L, C, R testing • Testing source frequency: 1 MHz to 300 MHz • Measuring time: 0.5 ms • Measure LCR and conduct frequency sweeps simultaneously
|
|
 |
IMPEDANCE ANALYZER IM7581
100kHz to 300MHz Measurement Frequency Impedance Analyzer with 0.5ms Test Speed

• |Z|, L, C, R testing • Testing source frequency: 100 kHz to 300 MHz • Measuring time: 0.5 ms • Measured value variability : 0.07% • Measure LCR and conduct frequency sweeps simultaneously
|
 |

IMPEDANCE ANALYZER IM7585
1MHz to 1.3GHz Measurement Frequency, 0.5ms Test Speed, and 0.07% Variability

• |Z|, L, C, R testing • Testing source frequency: 1 MHz to 1.3 GHz • Measuring time: 0.5 ms • Measured value variability : 0.07% • Measure LCR and conduct frequency sweeps simultaneously
|
|
 |

IMPEDANCE ANALYZER IM7583
1MHz to 600MHz Measurement Frequency and 0.5ms Test Speed

• |Z|, L, C, R testing • Testing source frequency: 1 MHz to 600 MHz • Measuring time: 0.5 ms • Measure LCR and conduct frequency sweeps simultaneously
|
 |
SMD TEST FIXTURE IM9100
High-precision four-terminal measurement for ultra small size 01005 (EIA)

• Direct connection type • SMDs with electrodes on the bottom • DC to 8MHz • Measurable sample sizes: 01005 to 0402 (EIA)
|
|
 |
CHEMICAL IMPEDANCE ANALYZER IM3590
Wide band 1mHz to 200kHz Chemical Impedance Analyzer for Testing Electrochemical Components and Materials, Batteries, and EDLC

• |Z|, L, C, R, σ, ε testing • Battery measurement • 1 mHz to 200 kHz • 2 ms measurement time
|
 |
EQUIVALENT CIRCUIT ANALYSIS FIRMWARE IM9000
Firmware Upgrade for the IM3570 Impedance Analyzer to Enable Cole-Cole Plots, Simple Circuit Analysis and Detailed Acceptance/Rejection Decisions

• Optional software for Model IM3570 • 5 equivalent circuit models • Plot frequency characteristics graph from analysis results • Cole-Cole plot, admittance circle display
|
|
 |
IMPEDANCE ANALYZER IM3570
Wide band 4Hz to 5Mz Impedance Analyzer for High Speed Testing and Frequency Sweeping of Piezoelectric Elements, Functional Polymer Capacitors, Coils and Transformers

• |Z|, L, C, R testing • 4 Hz to 5 MHz • 0.5 ms measurement time • Measure LCR and conduct frequency sweeps simultaneously
|
|
|
|
|
|
LCR Meters, 200 kHz to 8 MHz
 |
LCR METER IM3536
The New Standard for General-Purpose LCR Meters with Measurement Frequency from DC, 4Hz to 8MHz

• |Z|, L, C, R testing • Testing source frequency: DC, or 4 Hz to 8 MHz • Measuring time: 1 ms • Accuracy guaranteed range from 1mΩ • Continous testing under varying conditions
|
|
 |
LCR METER IM3523
Wide band 40Hz to 200kHz LCR Meter for High Speed Automated Testing on Production Lines

• |Z|, L, C, R testing • 40 Hz to 200 kHz • 2 ms measurement time
|
 |
LCR METER IM3533, IM3533-01
Wide band 1mHz to 200kHz LCR Meter for R&D Applications to Windings, Coil and Transformer Manufacturing

• |Z|, L, C, R testing • 1 mHz to 200 kHz • 2 ms measurement time • Transformer mode • Frequency sweep w/IM3533-01
|
|
|
|
LCR Meters | Capacitance Meters, 1 kHz, 120 Hz
 |
C METER 3506-10
Dual-band 1kHz/1MHz Capacitance Meter for High Speed Testing of Ceramic Capacitors on Production Lines

• C, D (tan δ), Q, and low capacitance testing • 1 kHz, 1 MHz • 1.5 ms measurement time at 1 MHz
|
|
 |
C HiTESTER 3504
Dual-band 120Hz/1kHz Capacitance Meter for High Speed Inspection of Multi-Layer Ceramic Capacitors (MLCC) on Taping Machines

• C, D (tan δ), high capacitance MLCC testing • 120Hz or 1kHz • 2 ms measurement time
|
 |
LCR HiTESTER 3511-50
Compact, dual-band 120Hz/1kHz LCR Meter for Integration into Automated Production Lines

• |Z|, L, C, R testing • 120Hz or 1kHz • 5 ms measurement time
|
|
|
|