1 800 665 7301 | info@tmetrix.com

  • Key Features Provide Application Versatility

    • USB, LAN (LXI), IEEE-488.2 and RS-232C with SCPI compatibility
    • Compatible with PPSC Studio graphical user interface
    • LabVIEW for Windows®/LabWindows® drivers
    • Waveform Creation by Harmonic Synthesis
    • Waveform Capture (Voltage and Current)
    • Harmonic Analysis (Voltage and Current)
    • Metering of RMS and Peak Values
    • Continuous Self Calibration (CSC)
    • Line Sync
    • 6:1 Peak Current Capability
    • Low Impedance for EN61000-3-2, 3 Testing
    • Programmable Output Impedance
    • Up to 0-300 VAC Direct Coupled Out
    • 1 Phase / 3 Phase Switch Selectable
    • 15-5000 Hz Full Power Bandwidth
    • Power Levels from 500 VA to 6 kVA standard; 30kVA optional
    • Externally Referenced Meter Calibration
    • CE Safety & EMC and NTRL Safety Mark

     

  • The Hioki PW8001 High-Precision Power Analyzer sets the benchmark for precision power analysis, offering unmatched accuracy and flexibility for evaluating motor and inverter efficiency. Supporting DC and frequencies from 0.1 Hz to 5 MHz, it features an 8-channel measurement capacity, enabling simultaneous analysis of complex systems like EV drivetrains, renewable energy sources, and high-efficiency SiC/GaN semiconductors.

    Equipped with advanced features such as automatic phase correction, intuitive Power Spectrum Analysis (PSA), and CAN/CAN FD integration, the PW8001 excels in capturing high-speed switching power fluctuations and harmonics. Its compatibility with high-voltage systems (up to 1500 V) and seamless connectivity with industry-standard software like LabVIEW and MATLAB ensure it meets diverse testing needs. With its robust design, real-time waveform visualization, and comprehensive motor analysis functions, the PW8001 is the ultimate tool for power conversion efficiency analysis.

     

    • Advanced semiconductor technology
    • High-quality construction
    • Rapid capacitor and pulse-forming network charging
    • Compact and lightweight design
    • Simple parallel operation for higher power needs
    • Compatible with worldwide input voltages and frequencies
    • Fully adjustable output voltage
    • Comprehensive remote control interface

     

  • The AZX Series (Regenerative AC / DC Power Source) is a family of high power, single, split and three phase, AC, DC and AC+DC output capable Power Sources with full energy recovery to the AC mains when sinking power from the equipment under test. Available models range from 30 kVA to 440 kVA. Using a modern color touch screen based user interface for ease of use, the AZX Series is cost effective and fully programmable for both basic frequency conversion and advanced AC power line or DC power disturbance test applications requiring up to 1000 Hz fundamental frequency.

    The energy recovery capability allows both sourcing and sinking of current and power up to 100% of rated power. Adding the Load Option (Option L) adds full electronic regenerative AC & DC Load programming capability to the AZX.

     

  • High-Speed Current Control: No dynamic overshoot or oscillation
    High Slew-Rate: Up to 30A/*s for fast load changes
    Low Voltage Operation: Stable operation with no turn-on delay
    Multi-Functional: Seven load modes and four operating modes
    Parallel Operation: Up to 10kW with 10 units
    User-Friendly Interface: Built-in USB and optional IEEE interfaces
    Compliance: EN61010-1 compliant with a two-year warranty

  • The new G5.RSS series features

    • High control dynamics
    • An exceptional accuracy
    • A nominal output voltage of up to 3000 VDC
    • A wide current-voltage range with an auto-ranging factor of 3.
    • You get the best value for your investment.

     

    • The S type Channel card provides economical, high-performance power measurement with a basic 0.1% accuracy and enough bandwidth to handle waveforms up to 1.25 MHz.
    • The A-type ultra-precision Channel card offers a 2-year accuracy rating of 0.03% of reading and bandwidth up to 1.25 MHz.
    • The W type Wideband Channel card performs precision power measurements on the toughest real-world waveforms, with sampling speed fast enough to tame waveforms up to 5Mhz

     

  • • High Power Accuracy of 0.045% For All Channels
    • Improved Voltage and Current Self-Heating Adders
    • Faster Sampling Rates & Bandwidth Performance
    • Greater Harmonic Frequencies

     

  • • Ultra High Power Accuracy of 0.024% For All Channels
    • Improved Voltage and Current Self-Heating Adders
    • Faster Sampling Rates & Bandwidth Performance
    • Greater Harmonic Frequencies

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +12 to -12 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510 MCOR12 Power Modules are identical and interchangeable.
    • Has two high-precision measurements of output current;
      • one is used to close the regulation control loop,
      • provides an independent monitoring signal to the Crate Interface Card.
    • Fault sensing circuitry in the module sets a Fault Latch which inhibits the output.
    • A (momentary) Sync input signal inhibits MOSFET switching when it is active (high);
      • this eliminate switching noise .
      • reduces power line noise during sensitive analog signal measurements.

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +30 to -30 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510R30 MCOR30 Power Modules are identical and interchangeable
      • Programming Card is plugged into the replacement module.
    • Each channel has a critically-damped, LC noise filter with a cut-off frequency of about 8 kHz.
    • A 16-pin front panel diagnostics connector taps onto major circuit nodes which enables quick “inthe-crate” fault evaluation

     

  • DC, 0.5 Hz to 200 kHz, 3-phase 4-wire, High Precision Power Analyzer for Motor and Inverter Efficiency Analysis

    Model No. (Order Code)

    PW3390-01
    PW3390-02 D/A output
    PW3390-03 D/A output, motor analysis

    Note: PW3390 by itself does not support current and power measurements. Optional current sensor and voltage cord are necessary to measure current or power parameters. Specify inclusion of Motor analysis & D/A output upon order for factory installation. These options cannot be changed or added after delivery.

    LANRS232C USB2 TrueRMS SDCE
  • 3-Phase 4-Wire Power Quality Analyzer Compliant to IEC61000-4-30 Class S Standards and On-screen Guide to Deliver Easy Setup and Testing

    Model No. (Order Code)

    PQ3100 main unit, clamp sensor is sold separately
    PQ3100-91 kit includes 600 A sensor × 2 and other options
    PQ3100-92 kit includes 600 A sensor × 4 and other options
    PQ3100-94 kit includes 6000 A sensor × 4 and other options

    Note: An optional current sensor is necessary to measure current or power parameters. Select from Value Kits for added savings.

    LANUSB 2.0CETrueRMS RS232CSD
  • Photovoltaic applications, the quality and technical data of the AC-DC converter is of primary interest. Solar installations are intended for a lifetime of roughly 20 years, therefore even fractions of a percent in efficiency will represent significant amounts of energy losses.

  • Programmable Grid-tie Sink High-Power DC Supply,

  • Programmable Grid-tie Source & Sink Technology
    Wide range of power 20 to 512 kW, expandable up to several MW
    DC output voltages from 0-65 VDC up to 0-1500 VDC, +/- 40 A up to +/- 600 A