1 800 665 7301 | info@tmetrix.com

Products


  • • Ultra High Power Accuracy of 0.024% For All Channels
    • Improved Voltage and Current Self-Heating Adders
    • Faster Sampling Rates & Bandwidth Performance
    • Greater Harmonic Frequencies

     

    • 3″ Color Touch Display – Easy To Use Intuitive User Interface
    • 6 Functions Choose From – AC/DC Hipot, IR, Ground Bond, Continuity & Built-in Switching
    • Made in the USA – Designed & Built in San Diego CA
    • Compact, Lightweight, Rugged, Fan Free, Fast (100mS min test time) & Accurate
    • 5KV AC/DC Hipot, 20mA max source current
    • Ground Bond 1-30A RMS (42 A peak), 100µΩ Resolution
    • 100 nano-Amp Leakage Current Resolution
    • Low Cost of Ownership – 2 Year Calibration Interval

     

  • AC Power Cords 14AWG PLUG-SJ 9FT (2.7m) BLACK

     

  • Key Performance Capabilities:

    • Slew rates up to 60 V/µsec.
    • Up to 240A DC at +50VDC or –50VDC (4301-240 configuration).
    • Can provide pulses of up to 800 amps at voltages of up to ±100V (4301-240 configuration).
    • Adjustable compensation allows the system to maintain a 50V/2 µsec rise-time over a wide range of current outputs.

     

  • Key Performance Capabilities:

    • Bandwidth: DC to 50 kHz
    • Voltage: 0 to 250 VRMS; 0 to 350 VDC
    • Current: 100 to 500 ARMS
    • Distortion: 0.1%
    • Power: 4 kW to 20 kW*Power levels up to 5X rated power when driving reactive loads
    • High power efficiency and density

    *Models available with output from 4 kW to 20 kW (capable of up to 125 kVA).

     

  • Key Performance Capabilities:

    • 4-Quadrant – Can source and sink current
    • ±80V – DC supply for 12V to 48V systems; meets 80V surge requirements
    • 300 kHz Sine – DC ripple tests for all major standards
    • 3µs Rise Time – Exceeds surge and dropout slew rate requirements
    • 3mΩ DC Source Impedance – Out-performs ISO 7637-2 requirements
    • Supports ground reference and supply offset testing required for ISO 16750-2 Sect. 4.8 and other similar standards

     

    • PowerFlex design gives variable voltage and current combinations within a maximum power envelope
    • Up to 60V and up to 20A per output (420W maximum)
    • Constant voltage or constant current operation
    • Low output noise and good transient response
    • PowerFlex or fixed-range operation plus custom limits
    • True analogue controls with digital settings locking
    • Independent outputs or isolated voltage tracking (dual)
    • Outputs can be wired in series or parallel for 120V or 40A
    • Variable OVP trips; safety binding-post terminals
    • 4 digit fixed resolution meters; selectable remote sensing
    • Compact ½ rack 3U case (dual) or ¼ rack 3U case (single)
    • Duplicate terminals at rear on CPX400SA, SP & DP
    • Isolated analogue control interface (CPX400SA only)
    • GPIB, RS-232, USB and LAN interfaces with LXI compliance (CPX400SP & CPX400DP only)

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +12 to -12 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510 MCOR12 Power Modules are identical and interchangeable.
    • Has two high-precision measurements of output current;
      • one is used to close the regulation control loop,
      • provides an independent monitoring signal to the Crate Interface Card.
    • Fault sensing circuitry in the module sets a Fault Latch which inhibits the output.
    • A (momentary) Sync input signal inhibits MOSFET switching when it is active (high);
      • this eliminate switching noise .
      • reduces power line noise during sensitive analog signal measurements.

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +30 to -30 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510R30 MCOR30 Power Modules are identical and interchangeable
      • Programming Card is plugged into the replacement module.
    • Each channel has a critically-damped, LC noise filter with a cut-off frequency of about 8 kHz.
    • A 16-pin front panel diagnostics connector taps onto major circuit nodes which enables quick “inthe-crate” fault evaluation

     

    • 2U Chassis – 19″ rack mount 3.48” Height, 9.60” Depth and Weight 6lb.
    • Power 120V AC 60Hz
    • Washable front removable air filter
    • Ball Bearing AC fans provide 330 CFM
    • Dual plenum design
    • Cooling for 160mm,220mm depth modules
    • Diverts lower warmed air to rear of Cabinet
    • RM option diverts lower air to front of Cabinet

     

    • accommodate these control schemes
    • total control system interface on a single VME-standard card
    • occupies the left-most slot of the crate
    • monitoring voltage reference inputs, output voltages and fault conditions
    • standard VMEbus-compatible 6U by 220 mm board installed
    • Eurocard crate
    • Two 96-pin I/O connectors

     

  • MCOR Modules

    MCOR 2/6/9/12

    Each module can be customized to provide maximum outputs of 2 amps, 6 amps, 9 amps, and 12 amps. Up to 16 of these can fit in a single 6U VME style crate.

    MCOR 30

    Each module can provide a maximum output 30 amps. Up to 8 of these can fit in a single 6U VME style crate.

    • Frequency Range 10 Hz – 1GHz, 3GHz or 6GHz
    • 4000x faster in your pre-certifcation work
    • compact design and +12V power supply
    • 162.5 MHz full gapless real-time analysis bandwidth
    • Weighted Real-time Spectrogram

     

    • requency Range from DC up to 40 GHz
    • 685 MHz Real-time analysis bandwidth
    • Dynamic range of more than 100 dB
    • Multi-GHz real-time scanning up to 40 GHz
    • all 6dB RBWs acc. to CISPR, MIL, DO, ANSI, FCC
    • fastest super-heterodyn receiver on the planet

     

  • • Wide-range Single-phase 85-265VAC input (47-63Hz)
    • Built-In RS-232/RS-485 interfaces
    • Multi-Drop (RS-485) Slave Interface (31 units)
    • Last-Setting Memory
    • High Resolution 16 bit ADC’s and DAC’s
    • Continuous Encoders for Voltage and Current Adjustment
    • Parallel Operation with Active Current Sharing and Current Sum
    • Independent Remote ON/OFF (Enable/Disable)
    • Remote Analog Programming (V/I) and Monitoring (V/I)
    • Modular and SMT design
    • 19” rack-mounted
    • Optional built-in LXI compliant LAN interface
    • Optional built-in IEEE (488.2/SCI) interface
    • Optional built-in USB (2.0) interface
    • Optional built-in Isolated Analog (5V/10V) interface
    • Software Drivers (LabView/LabWindows)
    • Worldwide Safety Agency approvals
    • CE Mark for LVD and EMC regulation
    • Five Year Warranty 
  • • Wide-range Single-phase 85-265VAC input (47-63Hz)
    • Built-In RS-232/RS-485 interfaces
    • Multi-Drop (RS-485) Slave Interface (31 units)
    • Last-Setting Memory
    • High Resolution 16 bit ADC’s and DAC’s
    • Continuous Encoders for Voltage and Current Adjustment
    • Parallel Operation with Active Current Sharing and Current Sum
    • Independent Remote ON/OFF (Enable/Disable)
    • Remote Analog Programming (V/I) and Monitoring (V/I)
    • Modular and SMT design
    • 19” rack-mounted
    • Optional built-in LXI compliant LAN interface
    • Optional built-in IEEE (488.2/SCI) interface
    • Optional built-in USB (2.0) interface
    • Optional built-in Isolated Analog (5V/10V) interface
    • Software Drivers (LabView/LabWindows)
    • Worldwide Safety Agency approvals
    • CE Mark for LVD and EMC regulation
    • Five Year Warranty