1 800 665 7301 | info@tmetrix.com

    • Versatile Current Sensing: Accurately measure small and large currents, from sub-milliamp levels to thousands of amps.
    • High-Speed Pulse Monitoring: Patented distributed termination technology enables ultra-fast rise time measurement (as short as 2ns).
    • Enhanced Noise Immunity & Safety: Double shielding minimizes external noise, making these monitors ideal for high-voltage applications.
    • Robust Construction: Sealed models are suitable for high-voltage insulating oil or vacuum environments.
    • Broad Compatibility: Works with oscilloscopes, spectrum analyzers, power analyzers, digital voltmeters, ADCs, and more.

     

  • High-Precision Current Measurement with BNC Connectivity

    • Precision Current Sensing: ±1% accuracy ensures reliable real-time current monitoring.
    • BNC Connector for Seamless Connectivity: Works with oscilloscopes, ADCs, spectrum analyzers, and power analyzers.
    • Clamp-On Design for Non-Intrusive Measurement: Safely monitor live current flow without circuit disruption.
    • 50 Ohm Termination Compatible: Output reduces by half when using a 50Ω termination.
    • High-Voltage Safety Considerations: Conductive case requires adequate insulation for user safety.

     

  • High-Precision Current Sensing with BNC Connectivity

    • High-Precision Measurement: ±1% accuracy for reliable current sensing.
    • Customizable Configurations: Designed to meet specific user requirements for precision measurement.
    • BNC Connector for Easy Integration: Works with oscilloscopes, ADCs, spectrum analyzers, and power analyzers.
    • Non-Insulated Conductive Case: Proper insulation must be provided on the monitored conductor.
    • 50 Ohm Termination Compatibility: Using a 50Ω termination reduces the output to half.

     

  • High-Precision Voltage Measurement Up to 500kV

    • High-Voltage Measurement Capability: Supports up to 500kV in insulating oil and customizable calibration for air use.
    • Precision Division Ratios: Models with 5000:1, 10,000:1, and custom ratios, ensuring reliable voltage scaling.
    • Temperature-Compensated Accuracy: ±1% over 20°C to 80°C, providing stable voltage readings.
    • Robust Design for Harsh Environments: Sealed for high-voltage insulating oil use, with custom air calibration available.
    • Safe Operation with Ground Loop Control: The outer conductor is isolated from the case, allowing controlled grounding connections.

     

  • Precision Pulse Output Up to 500kV

    • Wide Voltage Range: Supports 100kV to 500kV pulse outputs for high-energy applications.
    • Fast Pulse Transmission: Pulse durations from 0.25 to 50 microseconds, ensuring efficient energy transfer.
    • Insulating Oil Immersion: Open-construction design for operation in high-voltage insulating oil, reducing breakdown risks.
    • Advanced Overvoltage Protection: Designed with built-in safety factors (50-100%) to prevent damage from overvoltages.
    • Reliable Flashover Protection: Corona ring-to-core insulation prevents damage from accidental flashovers.

     

  • The EME Guard Plus is a lightweight and robust personal protection monitor designed to ensure the safety of workers operating near electromagnetic field (EMF) emitters such as antennas, radars, and base stations. With a frequency range of 1 MHz to 40 GHz, this device continuously monitors and records EMF exposure levels while providing immediate audio, visual, and vibrating alerts when exposure exceeds predefined safety thresholds. Customizable alarm settings and a triaxial isotropic probe ensure accurate and reliable measurements.

     

  • The EME Guard XS Radar is a state-of-the-art RF safety monitor, specifically designed for workers operating near radar transmitters and antennas. With its isotropic tri-axis E-field sensors, this compact device provides continuous EMF monitoring over a frequency range of 1 MHz to 40 GHz, including short pulsed signal detection. Equipped with audio and visual alarms, it alerts users instantly when EMF exposure exceeds predefined safety thresholds, creating a safer working environment for military, aviation, and telecom personnel.

     

  • Solutions For:

    •  Accurate measurement with tri-axis sensors
    • Instant audio and visual alarm
    • Robust, reliable and user-friendly
    • Covers 5G / 6G bands, measuring up to 71 GHz

    User profile:

    • Persons working near antennas including installation and maintenance workers, broadcast, PMR and mobile phone operators or regulatory body employees

    Measurement capabilities:

    • Continuous monitoring of Electromagnetic Field levels with isotropic tri-axis E-field sensors
    • EMF Level indicated by a LED color scale
    • Audio and visual alarms triggered when EMF exceeds the reference level
  •  

    • Reliable and Repeatable solid state signal generation
    • Standard Internal/external pulse modulation
    • USB/Ethernet Control
    • 10 MHz external or internal reference
    • 100 Hz Frequency Resolution
    • Easily portable
    • Sized to fit into a single rack unit for ATE applications

     

  •  

    • Reliable and Repeatable solid state digital attenuation
    • Includes GUI, Windows and Linux SDK, LabVIEW driver
    • Programmable attenuation ramp and fading profiles
    • Operate multiple devices directly from a PC or self-powered hub
    • Easily portable USB powered device
    • USB and Ethernet control interfaces

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +12 to -12 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510 MCOR12 Power Modules are identical and interchangeable.
    • Has two high-precision measurements of output current;
      • one is used to close the regulation control loop,
      • provides an independent monitoring signal to the Crate Interface Card.
    • Fault sensing circuitry in the module sets a Fault Latch which inhibits the output.
    • A (momentary) Sync input signal inhibits MOSFET switching when it is active (high);
      • this eliminate switching noise .
      • reduces power line noise during sensitive analog signal measurements.

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +30 to -30 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510R30 MCOR30 Power Modules are identical and interchangeable
      • Programming Card is plugged into the replacement module.
    • Each channel has a critically-damped, LC noise filter with a cut-off frequency of about 8 kHz.
    • A 16-pin front panel diagnostics connector taps onto major circuit nodes which enables quick “inthe-crate” fault evaluation

     

    • 2U Chassis – 19″ rack mount 3.48” Height, 9.60” Depth and Weight 6lb.
    • Power 120V AC 60Hz
    • Washable front removable air filter
    • Ball Bearing AC fans provide 330 CFM
    • Dual plenum design
    • Cooling for 160mm,220mm depth modules
    • Diverts lower warmed air to rear of Cabinet
    • RM option diverts lower air to front of Cabinet

     

    • accommodate these control schemes
    • total control system interface on a single VME-standard card
    • occupies the left-most slot of the crate
    • monitoring voltage reference inputs, output voltages and fault conditions
    • standard VMEbus-compatible 6U by 220 mm board installed
    • Eurocard crate
    • Two 96-pin I/O connectors

     

  • MCOR Modules

    MCOR 2/6/9/12

    Each module can be customized to provide maximum outputs of 2 amps, 6 amps, 9 amps, and 12 amps. Up to 16 of these can fit in a single 6U VME style crate.

    MCOR 30

    Each module can provide a maximum output 30 amps. Up to 8 of these can fit in a single 6U VME style crate.

    • provides precision bi-polar output currents
    • minimal zero-cross over distortion
    • 19” rack mounted 6U x 220 mm crate
    • crate has 17 slots; 16 (slot 0 thru 15)
    • connectors
      • J1 (ExtIntlk),
      • J2 (CrateOK),
      • J3 (Input Reference Voltages),
      • J4 (Output Monitors), and
      • J9 (Bitbus)