1 800 665 7301 | info@tmetrix.com

  • The Hi-Techniques Synergy series of Data Acquisition Systems integrates superior transient and streaming capability with optimized time and frequency domain performance. Add in universal signal conditioning, real-time math and you’ll see why Synergy is the ultimate Data Acquisition System for all of your mechanical, electrical, acoustic, shock and vibration measurements.

     

  • The Hi-Techniques Synergy series of Data Acquisition Systems integrates superior transient and streaming capability with optimized time and frequency domain performance. Add in universal signal conditioning, real-time math and you’ll see why Synergy is the ultimate Data Acquisition System for all of your mechanical, electrical, acoustic, shock and vibration measurements.

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Bidirectional (source & sink), Regenerative 0…65VDC to 0…1500VDC, 20kW up to 1.5 MW 

    • cell system nominal voltage and type of chemistry
    • number of cells
    • internal resistance and associated parameters
    • cell temperature progression
    • allowed current
    • charge efficiency
    • energy computing and management facilities
    • time-dependent and functional dependent parameters

     

    • Setting of operational parameters for each output phase: (frequency, phase, voltage, basic waveform)
    • Defining functional blocks enabling a wide variety of modulation capabilities
    • Defining, editing and storing of even complex and long test sequences
    • Preview window for output voltage waveforms
    • LC load mode, definition of complex equivalent circuits
    • Hand drawing curve tool and FOURIER tool (harmonics synthesis)
    • TC.ACS provides an extensive safety concept in order to detect unwanted or off-limit conditions very quickly and to initiate controlled limiting or even a shutdown.

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Phase -Models Kitted for installation into End User’s Cabinet  and Phase -Models including Cabinet and Emergency Power off  (EPO)1

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 60,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 166.7 / 83.3 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 527/240 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 60,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 166.7 / 83.3 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 527/240 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 125.0 / 62.5  (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 466/212 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 125.0 / 62.5  (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 466/212 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 25.0/13.9 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 15 (U) and Weight 320/146(LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 25.0/13.9 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 15 (U) and Weight 320/146(LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power 15000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 41.7 / 21.0 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power 15000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 41.7 / 21.0 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power  12000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS  33.3/16.7 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).