1 800 665 7301 | info@tmetrix.com

Uncategorized

Showing 1–16 of 23 results


  • Single-phase, 2U, industrial amplifier/battery simulator

    • Bench-sized
    • Powered from 120V/230VAC
    • Source and Sink (4 quadrant)
    • Rugged Design
    • 3-Year, No-Fault Warranty

    Key Performance Capabilities:

    • Drop outs and surges as fast as 1.2µs
    • Small signal response up to 1 MHz
    • 13.5 VDC at up to 28A
    • Field-selectable ±40V, 75V or 150V potential

     

  • The First Wide-Bandwidth, High-Power Digital Amplifiers

    • Max Continuous Output Current: 300A RMS
    • Surge Rating: 2X power at up to 400 VP or 750A
    • Apparent Power Rating: Up to 5X continuous power rating atup to 400 VP or 750A
    • Supply Voltage: Three-phase, 208V ±10%, 60A, 50/60 Hz; 400V ±10%, 15A version available.
    • Dimensions (HxWxD): 36.5 x 21.0 x 30.75 inches (92.7 x 53.3 x 78.1 cm)
    • Weight: Appx. 540 lbs. (244.9 kg)

     

  • The EME Guard Plus is a lightweight and robust personal protection monitor designed to ensure the safety of workers operating near electromagnetic field (EMF) emitters such as antennas, radars, and base stations. With a frequency range of 1 MHz to 40 GHz, this device continuously monitors and records EMF exposure levels while providing immediate audio, visual, and vibrating alerts when exposure exceeds predefined safety thresholds. Customizable alarm settings and a triaxial isotropic probe ensure accurate and reliable measurements.

     

  • The EME Guard XS Radar is a state-of-the-art RF safety monitor, specifically designed for workers operating near radar transmitters and antennas. With its isotropic tri-axis E-field sensors, this compact device provides continuous EMF monitoring over a frequency range of 1 MHz to 40 GHz, including short pulsed signal detection. Equipped with audio and visual alarms, it alerts users instantly when EMF exposure exceeds predefined safety thresholds, creating a safer working environment for military, aviation, and telecom personnel.

     

  • Key Performance Capabilities:

    • Slew rates up to 60 V/µsec.
    • Up to 240A DC at +50VDC or –50VDC (4301-240 configuration).
    • Can provide pulses of up to 800 amps at voltages of up to ±100V (4301-240 configuration).
    • Adjustable compensation allows the system to maintain a 50V/2 µsec rise-time over a wide range of current outputs.

     

  • Key Performance Capabilities:

    • Bandwidth: DC to 50 kHz
    • Voltage: 0 to 250 VRMS; 0 to 350 VDC
    • Current: 100 to 500 ARMS
    • Distortion: 0.1%
    • Power: 4 kW to 20 kW*Power levels up to 5X rated power when driving reactive loads
    • High power efficiency and density

    *Models available with output from 4 kW to 20 kW (capable of up to 125 kVA).

     

  • Key Performance Capabilities:

    • 4-Quadrant – Can source and sink current
    • ±80V – DC supply for 12V to 48V systems; meets 80V surge requirements
    • 300 kHz Sine – DC ripple tests for all major standards
    • 3µs Rise Time – Exceeds surge and dropout slew rate requirements
    • 3mΩ DC Source Impedance – Out-performs ISO 7637-2 requirements
    • Supports ground reference and supply offset testing required for ISO 16750-2 Sect. 4.8 and other similar standards

     

  • Key Performance Capabilities:

    • Up to 900 watts RMS power output (7136 model)
    • Small signal response up to 400 kHz
    • User-adjustable precision DC offset
    • User-adjustable current limit: 1A to 25A
    • 4-quadrant operation
    • AC/DC coupled

     

    • Dynamic set up: During a simple frame reading, users can define elements to be acquired, recorded, visualized and surveyed in real time.
    •  Macro-command: Users can write and execute complex test sequences thanks to macro-command functions.
    •  Local & Distant Integration: AT-DIAG can be driven and interrogated by external software. It can also be used with a computer through Ethernet.
    • Communication ports: Communication is done through RS232, NI CAN acq. Card, specific acquisition card or system.
    •  Protocols: FREERUNNING, KWP2000, CAN, LIN, FlexRay, ARINC, … Possibility to implement new protocols (customized protocol, …).
    •  Multi-product & Multi-protocol Communication: Communication can be set up with multiple addresses and protocols during a single test.

     

    • 1 software for all your equipment
    • 1 software for all standards
    • 1 software for your electrical and EMC tests
    • Advanced functions of monitoring and control
    • Automated reports
    • Team of specialists at your disposal

     

    • Fast: ACA compression and parallelization allow to speed up the calculation
    • Accurate: Fully validated with measurement results on real mock-up
    • Innovative: New method from research labs
    • Powerful: Compute very large models
    • Easy: Dedicated graphical user interface with modern layout

     

    • Fast: ACA compression and parallelization allow to speed up the calculation
    • Accurate: Fully validated with measurement results on real mock-up
    • Innovative: New method from research labs
    • Powerful: Compute very large models
    • Easy: Dedicated graphical user interface with modern layout

     

    • Unique user interface for all tests
    • Independent from any measuring device manufacturers
    • Free drivers and over 500 supported devices
    • Efficient and dedicated Technical support
    • Wide range of supported standards (ENxx, CISPR, AUTOMOTIVE, DO160, …)
    • Interface Agilent VEE™, WindowsLabView™, LabWindows CVI™, Visual C++
    • Operating system: Win XP, Vista, Seven, Windows 8
    • Report in MS Office™ 2003, 2007, 2010, 2013, Open office

     

  • Phase -Models Kitted for installation into End User’s Cabinet  and Phase -Models including Cabinet and Emergency Power off  (EPO)1

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 60,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 166.7 / 83.3 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 527/240 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 125.0 / 62.5  (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 466/212 (LBS./KG).

     


Showing 1–16 of 23 results