1 800 665 7301 | info@tmetrix.com

  • Applications:

    • Aerospace & Defense – Avionics, MIL-STD-704, EMC compliance, 400Hz & wild frequency testing
    • EV Charging & V2G/V2H Testing – On-board chargers, grid-tied inverters, smart grid simulation
    • Energy Storage & Renewable Systems – Home ESS, solar PV/grid-tied inverter testing
    • Industrial Power Simulation – Frequency conversion, harmonic analysis, transient simulations
    • Smart Grid & Compliance Testing – IEC 61000, RTCA DO-160, IEEE 1547, and more

     

  • Applications

    • Aerospace & Avionics – Frequency conversion (400Hz & wild frequency testing), MIL-STD compliance
    • EV Charging & Power Electronics – On-board chargers (OBC), V2G/V2H testing, battery simulation
    • Renewable Energy Systems – Solar PV/grid-tied inverter testing, home ESS & smart grid simulations
    • Power Supply & Industrial Testing – AC/DC power supply evaluation, network server & data center testing
    • Research & Development Labs – High-frequency power testing, compliance verification, transient simulations

     

  • High-Power 4-Quadrant AC & DC Power Source with Load Option

    • Powerful & Versatile: 12kVA / kW to 21kVA / kW in a 4U chassis. Parallel units up to 168kVA/kW (single cabinet)or 252kVA/kW (dual cabinet).
    • Multi-Phase Flexibility: Supports single-phase, split-phase, and three-phase configurations with AC, DC, or AC+DC output.
    • Grid Simulation & Compliance Testing: Emulates real-world power grid conditions, simulating disturbances, harmonics, and interharmonics for accurate renewable energy testing (solar inverters, EV charging, microgrid, and UPS applications).
    • Regenerative Efficiency: Over 90% energy recovery back to the grid reduces power consumption and operational costs.
    • Advanced Control & Monitoring: SmartSource Suite enables remote control via an intuitive web browser interface with LAN, USB, GPIB, and RS232 connectivity.

     

  • High-Power 4-Quadrant AC & DC Power Source

    • High Power Density: Available in 30kVA/kW, 45kVA/kW, and 55kVA/kW models, with parallel cabinets scaling up to 550kVA/kW.
    • Versatile Output Capability: AC, DC, or AC+DC modes in single-phase, split-phase, or three-phase configurations.
    • Dual Constant Power Voltage Ranges:
      • AC Voltage: 0-240V L-N / 0-415V L-L & 0-480V L-N / 0-830V L-L
      • DC Voltage: 0-340Vdc & 0-680Vdc
    • Grid Compliance Testing: Meets global standards like IEEE 1547, UL 1741, IEC 61000-3, IEC 61000-4
    • Regenerative Power Efficiency: >90% energy recovery back to the grid, reducing power waste and operational costs
    • PHIL Interface for Hardware-in-the-Loop (HIL) Testing: High-speed analog I/O for real-time frequency, voltage, and current control.
    • SmartSource Suite for Remote Testing: Web-based real-time monitoring and control via LAN, USB, GPIB, and RS232.

     

  • Pencil-style Pocket Digital Multimeter for General Electrical Maintenance, Testing and Hobbyists

    Key Features:

    • Test lead and main unit in a single body
    • Overload protection to 600 V at resistance or continuity functions
    • LED light brightly illuminates test points

     

  • The AZX Series (Regenerative AC / DC Power Source) is a family of high power, single, split and three phase, AC, DC and AC+DC output capable Power Sources with full energy recovery to the AC mains when sinking power from the equipment under test. Available models range from 30 kVA to 440 kVA. Using a modern color touch screen based user interface for ease of use, the AZX Series is cost effective and fully programmable for both basic frequency conversion and advanced AC power line or DC power disturbance test applications requiring up to 1000 Hz fundamental frequency.

    The energy recovery capability allows both sourcing and sinking of current and power up to 100% of rated power. Adding the Load Option (Option L) adds full electronic regenerative AC & DC Load programming capability to the AZX.

     

    • Available in 4.5-digit (60,000 count) and 6.5-digit (2,200,000 count) resolutions.
    • Wide measurement range:
      • DC Voltage: Up to 1000V
      • AC Voltage: Up to 750V (True RMS)
      • Current: 10A (AC/DC)
      • Resistance: 100MΩ (2-wire/4-wire)
      • Capacitance: 2nF – 100mF
      • Temperature measurements with TC and RTD sensor support.
    • High-speed measurements:
      • T3DMM4-5: 150 readings per second
      • T3DMM6-5: 10,000 readings per second
    • Advanced mathematical functions such as Max, Min, Standard Deviation, dBm/dB, Relative Measurement, Pass/Fail Analysis, and Histograms.
    • Connectivity: USB Device, USB Host, and LAN for remote operation via SCPI commands.
    • Data Storage: 1GB NAND flash memory for saving configuration files and test data.
    • Built-in cold junction compensation for accurate temperature measurements.
    • File management system supporting U-disc and local storage for convenient data access.
    • Comprehensive user interface with a dual-display system for easy navigation.
    • Automatic measurement functions, including statistical analysis, gating, and reference functions.

     

    • Maximum safety in the field by absolutely preventing short-circuit accidents with fused measurement terminals and current-limiting resistor
    • ±0.3% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
    • Low-pass filter (100 Hz/ 500 Hz) cuts high harmonics (when measuring inverter fundamental waveforms)
    • Connect to PC with USB communication function (optional)
    • Broad -25°C (-13°F) to 65°C (149°F) operating temperature range CAT IV 600 V, CAT III 1000 V

    予備  Guarantee3years  USB2  TrueRMS  CE DROPPROOF

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Bidirectional (source & sink), Regenerative 0…65VDC to 0…1500VDC, 20kW up to 1.5 MW 

    • cell system nominal voltage and type of chemistry
    • number of cells
    • internal resistance and associated parameters
    • cell temperature progression
    • allowed current
    • charge efficiency
    • energy computing and management facilities
    • time-dependent and functional dependent parameters

     

    • Setting of operational parameters for each output phase: (frequency, phase, voltage, basic waveform)
    • Defining functional blocks enabling a wide variety of modulation capabilities
    • Defining, editing and storing of even complex and long test sequences
    • Preview window for output voltage waveforms
    • LC load mode, definition of complex equivalent circuits
    • Hand drawing curve tool and FOURIER tool (harmonics synthesis)
    • TC.ACS provides an extensive safety concept in order to detect unwanted or off-limit conditions very quickly and to initiate controlled limiting or even a shutdown.

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Programmable Grid-tie Source & Sink Technology
    Wide range of power 20 to 512 kW, expandable up to several MW
    DC output voltages from 0-65 VDC up to 0-1500 VDC, +/- 40 A up to +/- 600 A

  • XJDeveloper is a graphical application that allows you to quickly and easily set up and run tests on your circuit. With XJDeveloper you can reduce your time to market by reusing your test scripts all the way through the product design process and then in manufacturing.