1 800 665 7301 | info@tmetrix.com

  • High-Power AC/DC Load Simulator with PHIL Interface

    • Scalable Power Density: Available in 30kVA/kW, 45kVA/kW, and 55kVA/kW models, with parallel cabinets up to 550kVA/kW.
    • Versatile AC/DC Load Capability: Supports single-phase, split-phase, three-phase, and multi-channel configurations.
    • Dual Constant Power Voltage Ranges:
      • AC Voltage: 5-220V L-N / 9-380V L-L & 5-440V L-N / 9-760V L-L
      • DC Voltage: 0-335Vdc & 9-650Vdc
    • Advanced PHIL Interface (Option H): High-speed analog I/O for real-time frequency, voltage, and current control.
    • Regenerative Power Efficiency: Returns over 90% of absorbed energy back to the grid, reducing operational costs & heat dissipation.
    • Dynamic Load Simulation: Simulates harmonics, transient conditions, and waveform distortions for real-world power testing.
    • SmartSource Suite for Remote Control: Web-based monitoring and test automation via LAN, USB, GPIB, and RS232.

     

  • Unleash the power of modern, versatile, and sophisticated AC sources with our LSX Series – Programmable AC Power Source. These powerhouses come in single and three-phase options, ranging from 1.5kVA to 6kVA. Equipped with an advanced programmable controller featuring a vivid colour touchscreen interface, the LSX Series is not just cost-effective but also fully programmable for basic frequency conversion, advanced AC power line disturbance tests, and ATE applications.

     

  • Key Features Provide Application Versatility

    • USB, LAN (LXI), IEEE-488.2 and RS-232C with SCPI compatibility
    • Compatible with PPSC Studio graphical user interface
    • LabVIEW for Windows®/LabWindows® drivers
    • Waveform Creation by Harmonic Synthesis
    • Waveform Capture (Voltage and Current)
    • Harmonic Analysis (Voltage and Current)
    • Metering of RMS and Peak Values
    • Continuous Self Calibration (CSC)
    • Line Sync
    • 6:1 Peak Current Capability
    • Low Impedance for EN61000-3-2, 3 Testing
    • Programmable Output Impedance
    • Up to 0-300 VAC Direct Coupled Out
    • 1 Phase / 3 Phase Switch Selectable
    • 15-5000 Hz Full Power Bandwidth
    • Power Levels from 500 VA to 6 kVA standard; 30kVA optional
    • Externally Referenced Meter Calibration
    • CE Safety & EMC and NTRL Safety Mark

     

  • The AZX Series (Regenerative AC / DC Power Source) is a family of high power, single, split and three phase, AC, DC and AC+DC output capable Power Sources with full energy recovery to the AC mains when sinking power from the equipment under test. Available models range from 30 kVA to 440 kVA. Using a modern color touch screen based user interface for ease of use, the AZX Series is cost effective and fully programmable for both basic frequency conversion and advanced AC power line or DC power disturbance test applications requiring up to 1000 Hz fundamental frequency.

    The energy recovery capability allows both sourcing and sinking of current and power up to 100% of rated power. Adding the Load Option (Option L) adds full electronic regenerative AC & DC Load programming capability to the AZX.

     

  • The Hi-Techniques FreeStyle series of Data Acquisition Systems is a versatile, capable solution for mobile and rugged data acquisition applications. FreeStyle was designed from the ground up to make data acquisition as fast and as easy as possible. Just grab your FreeStyle and your computer and head out to the test site.

    Flexibility by Design

     

  • The Hi-Techniques Synergy series of Data Acquisition Systems integrates superior transient and streaming capability with optimized time and frequency domain performance. Add in universal signal conditioning, real-time math and you’ll see why Synergy is the ultimate Data Acquisition System for all of your mechanical, electrical, acoustic, shock and vibration measurements.

     

  • The Hi-Techniques Synergy series of Data Acquisition Systems integrates superior transient and streaming capability with optimized time and frequency domain performance. Add in universal signal conditioning, real-time math and you’ll see why Synergy is the ultimate Data Acquisition System for all of your mechanical, electrical, acoustic, shock and vibration measurements.

     

  • Phase -Models Kitted for installation into End User’s Cabinet  and Phase -Models including Cabinet and Emergency Power off  (EPO)1

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 60,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 166.7 / 83.3 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 527/240 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 60,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 166.7 / 83.3 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 527/240 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 125.0 / 62.5  (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 466/212 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 125.0 / 62.5  (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 466/212 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 25.0/13.9 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 15 (U) and Weight 320/146(LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 25.0/13.9 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 15 (U) and Weight 320/146(LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power 15000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 41.7 / 21.0 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).