  • Bench System DC Power Supply, Linear Regulation, Smart Analog Controls Single, Dual or Triple Outputs, 48 to 242 watts, with/without Remote Interfaces
    • Single, dual or triple output models
    • Models from 6V/8A up to 60V/1.5A
    • Linear regulation – for the best performance
    • Ultra-compact design – uses up less space
    • True Analogue controls – for ease of use
    • S-Lock function – instantly lock settings
    • V-Span function – customize the voltage range
    • Low current range and current meter averaging
    • DC output switches and “view limits” button
    • Selectable remote sense terminals
    • Independent, Isolated Tracking, Ratio Tracking  and True Parallel modes on dual & triple models
    • High current low voltage output on triple output model
    • RS-232, USB and LAN (Ethernet), GPIB optional (P models)
    • LAN Interface conforms with LXI standard (P models)
    • Analogue remote control of V and I (single output P models)
    • Front and rear terminals (P models)

     

  • Bench DC Power Supply, Mixed-mode Regulation, Analog Controls Single, Dual or Triple Outputs, 175 to 420 watts

     

    • Single outputs, 35V/5A, 18V/10A, 42V/10A, 20V/20A
    • Dual or triple outputs, 35V/4A
    • Independent digital voltage and current meters for each output with 4 digit resolution
    • Switchable local or remote sensing
    • Constant voltage or constant current operation
    • Variable 1.5 – 5.0V auxiliary output at 5A (EX354RT)
    • Compact design uses less bench space
    • Silent fan-free cooling (not EX202R/EX4210R)
    • DC output switches, automatic mode indication
    • RS232 or USB controlled models available (35V/5A single)
    • Multi-mode dual model 2x(75V/2A) or 75V/4A or 150V/2A

     

  • Bench DC Power Supply, Linear Regulation, Analog Controls Single, Dual or Triple Outputs, 30 to 130 watts

    • Single outputs, 30V/1A, 18V/3.3A, 56V/1.1A, 15V/5A, 30V/3A
    • Single, dual or triple outputs, 30V/2A
    • Independent digital voltage and current meters  for each output with 4 digit resolution
    • Switchable local or remote sensing
    • Constant voltage or constant current operation
    • Variable 1.5 – 5.0V auxiliary output at 2A (EL302RT)
    • Compact design uses less bench space
    • Silent fan-free cooling
    • DC output switches, automatic mode indication
    • RS232 or USB controlled models available (30V/2A single)

     

     

  • Laboratory DC power supplies intended for standard bench-top applications or remote control and system use.

     

  • Model #

    Max
    Pulse
    Voltage

    (in oil)

    Max
    Pulse
    Voltage
    (in air)

    Voltage
    Division
    Ratio

    (in oil)

    Freq
    Range
    (1MΩ Load)
    Droop
    Rate
    (per µsec)
    Usable
    Rise
    Time
    Capacitance
    (approx)
    VD-500A 500kV 90kV   10,000:1 15Hz ~ 2MHz 0.01% 200ns 38pf

     

     

  • Model #

    Max
    Pulse
    Voltage

    (in oil)

    Max
    Pulse
    Voltage
    (in air)

    Voltage
    Division
    Ratio

    (in oil)

    Freq
    Range
    (1MΩ Load)
    Droop
    Rate
    (per µsec)
    Usable
    Rise
    Time
    Capacitance
    (approx)
    VD-305A-AIR 50kV   5000:1 70Hz ~ 4MHz 0.05% 100ns   8pf

     

  • Model #

    Max
    Pulse
    Voltage

    (in oil)

    Max
    Pulse
    Voltage
    (in air)

    Voltage
    Division
    Ratio

    (in oil)

    Freq
    Range
    (1MΩ Load)
    Droop
    Rate
    (per µsec)
    Usable
    Rise
    Time
    Capacitance
    (approx)
    VD-305A-10,000 300kV 50kV   10,000:1 30Hz ~ 4MHz 0.02% 100ns 18pf

     

  • Model #

    Max
    Pulse
    Voltage

    (in oil)

    Max
    Pulse
    Voltage
    (in air)

    Voltage
    Division
    Ratio

    (in oil)

    Freq
    Range
    (1MΩ Load)
    Droop
    Rate
    (per µsec)
    Usable
    Rise
    Time
    Capacitance
    (approx)
    VD-301 400kV 75kV    5000:1 25Hz ~ 3MHz 0.15% 150ns 28pf

     

  • Power Demand Analyzer (Custom 5000A Kit)

     

    • Supports single to three-phase, 4-wire circuits
    • Measure up to 780 V with a 1000 V display range
    • Simultaneously measure up to three single-phase, 2-wire circuits (in the same power system)
    • Broadly applicable for many jobs, including leakage current measurement (An optional clamp-on leakage sensor measures as low as 50 mA)
    • Store months of data on SD cards
    • Identifies your power condition to help save energy
    • The QUICK SET function guides you in making the right connections
    • Choose PW3360-21 for harmonic measurements up to the 40th order

     

  • Next-gen Time-Domain Reflectometers replace the Tektronix® 1502C

    The new CT100 and CT100HF are the industry’s highest-resolution portable metallic TDRs, designed for testing all coaxial and twisted-pair cables and interconnects used in modern microwave/RF and digital systems. These are the only portable instruments that exceed all TDR specifications of the Tektronix® 1502C Metallic TDR Cable Tester, while providing next-generation improvements in TDR analysis, data storage, connectivity, and ergonomics.

    CT100 Series TDRs feature 8-10x sharper spatial resolution and100-1000x better Distance-to-Fault (DTF) resolution than competing TDR instruments, and have multi-GHz bandwidth similar to competing FDR (Frequency-Domain Reflectometer) instruments with similar or better cable fault sensitivity andorders-of-magnitude better DTF precision.

    These instruments’ unique combination of fast system rise-time,high-resolution time-base, and precision 16-bit impedance measurements allow you to identify and correct subtle changes in cable and connector performance before system failure. Some of the CT100 Series’ innovative features are described below. Also, please read CT100 Series Features for more information.

     

  • Single-Phase and Three-Phase Handheld Power Meter with Harmonic Analysis Up to 20th Order

     

  • 3-Phase 4-Wire Portable Power Quality Analyzer to Detect, Measure and Record Power Quality Issues, Harmonics, Demand, Inrush and Power Transients

     

  • Analyze and Graph Data Captured by Hioki Power Quality Analyzers on a Windows PC

     

  • 3-Phase 4-Wire Power Quality Analyzer Compliant to IEC61000-4-30 Class A Standards with Dynamic 1300V Range, Harmonic and Inter-harmonics Analysis Capabilities

     


Showing 177–192 of 312 results