  • Multi-Range DC Power Supply with digital control, 3 or 4 Outputs, 315 to 420W with/without Remote Interfaces

    • hree or four high performance outputs each with full functionality
    • Range switching gives variable voltage/current combinations
    • Shared power mode provides double power from a single output
    • Low output noise and ripple via linear final regulation
    • High setting resolution of up to 1mV and 0.1mA
    • Variable OVP and OCP trips on all outputs
    • 50 setting memories per output plus 50 linked memories
    • Selectable voltage tracking (isolated tracking)
    • Selectable current meter averaging
    • Switchable remote sense capability
    • Graphic LCD provides simultaneous output metering
    • Numeric or spin-wheel control of all parameters
    • Individual or combined output on/off control with programmable delay sequencing.
    • 3U half-rack case for bench or rack mounting (4U rack kit accessory available)
    • RS-232, USB and LAN (LXI) interfaces (P models), GPIB option
    • Duplicate power & sense terminals at rear (P models)

     

  • with 10MHz to 3.6 or 6.0GHz bandwidth options

    True hand-held battery powered RF spectrum analyzers.

    • 10MHz to 3600MHz or 6000MHz frequency range
    • Resolution bandwidths from 300Hz to 10MHz (1:3:10)
    • -120dBm typical noise floor at -40dBm ref. level/10kHz RBW
    • Measurement in dBm or dBµV, mV or µW
    • Zero span mode with AM and FM audio demodulation
    • Trace modes of normal, peak hold and trace average
    • Live, View and Reference traces in contrasting colours
    • Twin markers with readout of absolute & difference values
    • Smart marker movement with selectable peak tracking
    • Frequency counter with down to 10Hz resolution
    • Frequency presets and independent state storage
    • Auto-find automatically sets sweep parameters for the highest signal found
    • Unlimited storage for waveforms, set-ups and screens
    • User assignable file names, file stamping from real-time clock
    • USB interfaces for Flash drives and PC connection
    • Comprehensive status and context sensitive help screens
    • Rechargeable lithium ion battery giving more than 3 hours continuous operation from a charge
    • Smaller and lighter than other spectrum analyzers (weight only 0.56 kg)

     

  • DC Power Supply single output, 80V/50A 750W PowerFlex+, LAN & USB interfaces, GPIB Option

    • Wide range of voltage/current combinations
    • Up to 80V and up to 50A within the same power envelope
    • Low output ripple and noise of <3mV rms at full power
    • High setting resolution of 1mV
    • Analogue control interfaces for voltage and current
    • Bench or rack mounting, front and rear terminals
    • LAN (LXI), USB, GPIB interfaces (GPIB optional on QPX750SP)

     

    • 150kHz to 3GHz (TGR2053) and 150kHz to 1.5GHz (TGR2051) frequency range
    • High signal purity, phase noise <-117dBc/Hz (typical) at 1GHz output and 10kHz offset
    • Amplitude range of -127dBm to +13dBm
    • 0.1dBm amplitude setting resolution
    • Internal or external analogue modulations (AM, FM, PM)
    • Amplitude can be set in dBm, dBμV or in linear Volts.
    • Internal or external digital modulations – ASK, OOK, FSK, 3FSK, 4FSK, GFSK, MSK, GMSK, HMSK & PSK with U01 option
    • Modulation Synchronisation
    • Fast amplitude and/or frequency sweeps with comprehensive triggering
    • 5ms sweep settling time
    • 1ppm frequency accuracy, <1ppm drift in first year
    • Modulation waveform output on the rear panel
    • Internal waveforms include: Sine, Square, Ramp, Triangle, PRBS (various lengths) and user-defined pattern
    • Simple operation with the colour touch screen
    • Programmable via USB, LAN (LXI) and GPIB (optional), SCPI compatible
    • Compatible with previous Aim-TTi RF generators

     

  • The DCP-X probe is designed for engineers and scientists in device characterization, R&D, and testing, offering highly accurate and repeatable on-wafer electrical measurements (IV, CV, LFN). It uses MEMS technology to measure advanced devices (2, 3, 5 nm) on various pad materials, micro-bumps, and pads as small as 20 μm, reducing the need for retesting and cleaning while covering the full thermal range at lower testing costs. Compared to traditional probes, the DCP-X provides 1000x lower contact resistance, minimal skate, and over 500,000 contact cycles, ensuring precise measurements and longer probe life.

  • The EME Guard Plus is a lightweight and robust personal protection monitor designed to ensure the safety of workers operating near electromagnetic field (EMF) emitters such as antennas, radars, and base stations. With a frequency range of 1 MHz to 40 GHz, this device continuously monitors and records EMF exposure levels while providing immediate audio, visual, and vibrating alerts when exposure exceeds predefined safety thresholds. Customizable alarm settings and a triaxial isotropic probe ensure accurate and reliable measurements.

     

  • The EME Guard XS Radar is a state-of-the-art RF safety monitor, specifically designed for workers operating near radar transmitters and antennas. With its isotropic tri-axis E-field sensors, this compact device provides continuous EMF monitoring over a frequency range of 1 MHz to 40 GHz, including short pulsed signal detection. Equipped with audio and visual alarms, it alerts users instantly when EMF exposure exceeds predefined safety thresholds, creating a safer working environment for military, aviation, and telecom personnel.

     

  • The EMI 64k software allows to embed the TDEMI systems in a fully automated test environment.

    • Full automation of EMI testing according to all commercial and military standards
    • Automated control of turntable, antenna and other equipment
    • Height and Angular Scan
    • Procedures according to standards as well as customized procedures
    • Reducing the cost for EMC and communication testing and certification by tailored packages

     

  • The measurement system for all emission measurments in the frequency range 1 Hz – 44 GHz.

    • Frequency Range  1 Hz – 30MHz, 1GHz, 3GHz, 6GHz, 9GHz, 18GHz, 26GHz, 40 GHz and 44GHz
    • 225 MHz Real-time Analysis Bandwidth
    • Weighted Real-time Spectrogram up to 44 GHz
    • CISPR Bandwidths 200 Hz, 9 kHz, 120 kHz, 1 MHz
    • MIL/DO Bandwidths 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz

     

  • The measurement system for all emission measurments in the frequency range 1 Hz – 44 GHz.

    • Full compliance EMI Reciever according to standard CISPR 16-1· 1, ANSI C63.2, MIL->461, and DO·160
    • Spectrum Analyzer
    • Integrated LOW Noise Ampllfier (lNAI)
    • Integrated Preselect1on
    • Tradttional and FFT·based Mode
    • Automatic Stepped Attenuator
    • Ultra Low Noise Floor
    • Excellent spurious Performance
    • Real-time Spectrum Analyzer optional
    • Vast IQ-Bandwidth

     

  • TDEMI Mobile+. The ultra mobile EMI receiver – Emission measurements everytime, everywhere. Fully stand-alone operable.

    • Frequency Ranges 10Hz – 1GHz, 3GHz, 6GHz or 7GHz
    • 16000x faster than conventional receivers
    • Super compact design and 12V supply
    • 225 MHz fully gapless real-time analysis bandwidth
    • Weighted Real-time Spectrogram

     

  • Ultra High Performance RT Spectrum Analyzer. Ultrafast EMI Measurements.

    • Frequency Range from 1 Hz up to 50 GHz
    • 225 MHz Real-time analysis bandwidth
    • 100 dB Dynamic Range
    • Ultrahigh performance preselection in all modes
    • Up to 510 MHz Real-time IQ-Analysis bandwidth
    • Ultra High Performance Spectrum Analyzer

     

     

  • Key Features:

    • Measure even harmonic waveform components using the True RMS method
    • Expanded -25°C to 65°C operating temperature range
    • Connect the CT6280 flexible sensor to measure up to 4199 A in thick or paired wires
    • Drop proof design withstands drop from a height of 1 meter

     

    • CAT IV 600 V, CAT III 1000 V
      When using P2000: CAT III 2000 V, CAT IV 1000 V
    • Easily get into tight spaces between cables thanks to thin sensor with a minimum cross-section span of 11 mm
    • Measure up to 2000 A AC
    • AC A, AC and DC V, DC+AC V, resistance, frequency, and more
    • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file (*1)
    • Harmonic analysis from 1st to 30th order with GENNECT Cross (*1)

     

  • Pencil-style Pocket Digital Multimeter for General Electrical Maintenance, Testing and Hobbyists

    Key Features:

    • Test lead and main unit in a single body
    • Overload protection to 600 V at resistance or continuity functions
    • LED light brightly illuminates test points

     

    • Simply clip clamps onto wire insulation
    • Green LED arrow clearly shows phase direction, perfect for visual reports
    • CAT III 1000V
    • Rotating LED indicator shows the phase sequence for a 3-phase power supply at a glance
    • Intermittent beeps signal positive phase; continuous tone signals reverse phase
    • Magnetic base allows the instrument to be secured on a distribution panel

     