AR RF/Microwave FL8000 Series of Electric Field Probes

AR RF/Microwave FL8000 Series of Electric Field Probes

  • Accurate field measurements ensure EMC lab measurements meet test standard requirements
  • Separable-axis field probe capable of measuring both continuous wave & pulse electric fields
  • Use of laser to deliver power-over-fiber allows continuous operation without recharging or replacing batteries
  • Correction factors from accredited ISO 17025 lab

 

REQUEST A QUOTE
SKU: FL8000 Category:



Introducing the AR RF/Microwave FL8000 Series of Electric Field Probes

The FL8000 series is an advanced line of laser-powered Electric Field Probes, and associated Kits designed specifically for EMC radiated immunity test applications. Each Field Probe is an electrically small, separable axis sensor capable of measuring both continuous wave and pulsed electric fields. There are a total of five Field Probes available, each with a unique bandwidth, sensitivity, and dynamic range.

The filed probe kits contain everything needed to operate its associated Field Probe. Remote control and laser power for the Field Probe is provided by the FI8000 Laser Probe Interface. A set of 20-meter fiber-optic extension cables and fiber-optic mating adapter are also provided with the kit. The use of a laser to deliver power-over-fiber (PoF) allows for continuous operation without recharging or replacing batteries. Additionally, this provides excellent RF isolation for the control system.

An ortho-angle mount and adapter foot are provided for ease of mounting in common orientations. When rotated about its ortho-angle mount, the probes provide excellent isotropic response. Attention was given to the mounting geometry and remote command set for the FL8000 series kits to allow seamless substitution with the legacy field probe kits.

Correction factors from an accredited ISO 17025 calibration lab are provided with each Field Probe. These factors can be loaded into a model FM7004A Field Monitor (sold separately) to automatically correct the probe
readings at user-specified frequencies. When correction factors are applied, the true accuracy of the Field Probe can be realized.

The export classification for this equipment is EAR99. This equipment is controlled for export in accordance with the U.S. Export Administration Regulations. Diversion contrary to U.S. law is prohibited.

AR RF/Microwave FL8000 Series of Electric Field Probes



AR RF/Microwave FL8000 Series of Electric Field Probes

Key Features

  • Accurate field measurements ensure EMC lab measurements meet test standard requirements
  • Separable-axis field probe capable of measuring both continuous wave & pulse electric fields
  • Use of laser to deliver power-over-fiber allows continuous operation without recharging or replacing batteries
  • Correction factors from accredited ISO 17025 lab

The filed probe kits contain everything needed to operate its associated Field Probe:

  • FI8000 laser probe interface
  • 20 m fiber-optic cable set
  • Fiber-optic mating adapter set
  • 0.5 m fiber-optic jumper cable
  • Calibration Report from an ISO 17025-accredited lab
  • Mini-tripod
  • Carrying case

 



Key Benefits

Application Standards:

  •  Automotive EMC
  • Commercial EMC
  • Aviation EMC
  • Military EMC
  • Wireless R&D

Correction factors from an accredited ISO 17025 calibration lab are provided with each Field Probe. These factors can be loaded into a model FM7004A Field Monitor (sold separately) to automatically correct the probe
readings at user-specified frequencies. When correction factors are applied, the true accuracy of the Field Probe can be realized.

The export classification for this equipment is EAR99. This equipment is controlled for export in accordance with the U.S. Export Administration Regulations. Diversion contrary to U.S. law is prohibited.

 


AR RF/Microwave FL8000 Series of Electric Field Probes


Trust the Experts at ACA TMetrix Inc.

ACA TMetrix Inc. is a leading Canadian distributor of test and measurement instruments and design tools. For over 55 years we have provided products manufactured by the world’s leading instrument manufacturers. Leading Distributor of Design Tools and Test Equipment in Canada.

Specifications

Probe Probe probe probe probe
Probe Model Number FL8200 FL8009 FL8018 FL8040 FL8060
Frequency Range 5 kHz – 200 MHz 20 MHz – 9.3 GHz 20 MHz – 18 GHz 20 MHz – 40 GHz 20 MHz – 60 GHz
Axis Type Separable X-Y-Z Axis
Measurement Type CW, AM & Pulse
Field Strength Range (Single Range) 0.3 – 500 V/m 0.5 – 800 V/m 2 – 1000 V/m
Dynamic Range 64 dB 54 dB
Analog Rise Time (10 – 90% Typical) 300 us 300 ns 600 – 2400 ns (amplitude dependent)
Isotropic Deviation (Measured at Ortho Angle) ±0.5 dB @ 10 MHz ±0.5 dB @ 100 MHz
Resolution < 0.1 dB
CW Damage Level 1000 V/m 1200 V/m
Pulse Damage Level 5 kV/m (> 0.1% Duty) 6 kV/m (> 0.1% Duty)
Linearity Error ±0.5 dB or ±0.3 V/m (Whichever is greater) ±0.5 dB or ±0.3 V/m (Whichever is greater) (±2.0 dB 20 MHz – 80 MHz) ±0.5 dB
Temperature Stabiliy (Over Operating Temperature Range) ±0.1 dB (Detection Circuit) ±0.5 dB (Complete System) ±0.5 dB
Weight 150 g (5.3 oz) 227 g (8.0 oz)
Dimensions (W x H x D) 42.3 x 52.4 x 52.4 mm (1.66 x 2.06 x 2.06 in) 29.2 mm (1.15 in) Spherical housing diameter 16.5 mm (0.65 in) Sensor radome height per axis 278 x 65 x 65 (10.9 x 2.6 x 2.6 in) 65 mm (2.6 in) Sensor head diameter

Data Response

Internal Sampling Rate 2 Msps
Sampling Window 4 ms
Time Between Sampling Windows 30 ms
Minimum Pulse Width 1 ms 1 us 2 us (40 – 1000 V/m) Usable to 1 us (70 – 1000 V/m)

Amplitude Accuracy (field aligned with sensor axis)

Without Correction Factors Applied ±1.0 dB @ 10 MHz ±1.0 dB @ 100 MHz

Environmental

Operating Temperature 10° to +40° C
Storage Temperature -20° to +50° C
Operating Altitude Up to 2000 m
Shock & Vibration Normal Truck Transport

Fiber-Optics

Connector Type E – 2000 Compact Duplex
Bend Radius >30 mm
Pigtail Length (With Verification Loop) 1 m
Maximum Single F/O Extension Length 100 m Contact AR Applications Team for requirements greater than 100 m.

 

Datasheet


Get in touch with us to inquire about our tailored consulting services.