LMX Series – High Performance Linear AC Power Source up to 6kVA, or 30kVA option

LMX Series – High Performance Linear AC Power Source up to 6kVA, or 30kVA option

  • High Performance Linear AC Power Sources
  • Power range: 500VA to 30kVA
  • Single-phase and three-phase models available
  • Frequency range: 15 to 5,000 Hz
  • Output voltage range up to 600Vrms L-N
  • Linear amplifiers for high crest factor and low-distortion waveforms
  • Backward compatible with AMX Series
  • Stand-alone models up to 6kVA; paralleled systems up to 30kVA
  • Low acoustic noise design
  • Easy installation and operation
  • Suitable for frequency conversion, power-line susceptibility testing, and transient simulation

 

REQUEST A QUOTE
Category:



Introducing the LMX Series – High Performance Linear AC Power Source up to 6kVA, or 30kVA option

When high power quality matters, the new for 2020 LMX Series family of High Performance Linear AC Power Sources is the answer. The linear amplifiers within the LMX Series power sources are unmatched in their ability to produce the high crest factorlow-distortionhigh fidelity output waveforms required by the most demanding AC Test Power applications. Stand-alone models range from 500 VA to 6 kVA. Larger chassis may be paralleled to create systems that range from 8kVA to 30 kVA. Offering both single and three phase models, units are conservatively designed with output power ratings based on the most severe combination of input line, output voltage, power factor, and temperature.
LMX Series – High Performance Linear AC Power Source up to 6kVA, or 30kVA option



LMX Series – High Performance Linear AC Power Source up to 6kVA, or 30kVA option

Key Features

  • USB, LAN (LXI), IEEE-488.2 and RS-232C with SCPI compatibility
  • Compatible with PPSC Studio graphical user interface
  • LabVIEW for Windows®/LabWindows® drivers
  • Waveform Creation by Harmonic Synthesis
  • Waveform Capture (Voltage and Current)
  • Harmonic Analysis (Voltage and Current)
  • Metering of RMS and Peak Values
  • Continuous Self Calibration (CSC)
  • Line Sync
  • 6:1 Peak Current Capability
  • Low Impedance for EN61000-3-2, 3 Testing
  • Programmable Output Impedance (R+L) both Real-Time & RMS modes
  • Up to 0-300 VAC Direct Coupled Out
  • 1 Phase / 3 Phase Switch Selectable
  • 15-5000 Hz Full Power Bandwidth
  • Power Levels from 500 VA to 6 kVA standard; 30kVA optional
  • Externally Referenced Meter Calibration
  • CE Safety & EMC and NTRL Safety Mark

Special LMX Series Features

  • Continuous Self Calibration: Ensures AC output voltage accuracy at ±0.03%.
  • Waveform Edit: Modify stored waveforms by specifying amplitude at each phase angle.
  • Programmable Dynamic Output Impedance: Adjusts impedance to simulate line or transformer losses, compensating up to ±10% of output voltage.
  • Waveform Analysis: Displays harmonic structure with magnitude, THD, odd/even distortion in %.
  • Waveform Synthesis: Create any AC Test Waveform by inputting harmonics, amplitude, and phase angles up to the 51st.
  • Waveform Library: Store up to 200 waveforms for steady-state or transient tests. Memory #1 is a high-res sine wave, others are editable.
  • Time-Based Transients: Create linear transients to modify voltage or frequency over a set time.
  • Cycle-Based Transients: Execute waveform transients for 1 to 100 cycles.


Key Benefits

  • Real-Time Programmable Controller: Complete control over AC power form and output
  • Continuous Self Calibration: Exceptional voltage accuracy at ±0.03%
  • Waveform Edit: Customize waveforms by specifying amplitude at each phase angle
  • Programmable Dynamic Output Impedance: Simulate line or transformer losses, adjust impedance up to ±10%
  • Waveform Analysis: Detailed harmonic structure display with magnitude and distortion metrics
  • Waveform Synthesis: Create custom AC Test Waveforms with harmonics up to the 51st
  • Waveform Library: Store and execute up to 200 different waveforms for various tests
  • Time-Based Transients: Linear voltage or frequency modifications over set time segments
  • Cycle-Based Transients: Execute transient waveforms for 1 to 100 cycles
  • Ease of Use: Control via front panel, USB, LAN, RS-232, or IEEE 488.2/SCPI BUS
  • Browser Interface: Remote control using a web browser on PC, laptop, or smartphone
  • Versatile Applications: Suitable for various test power applications demanding high quality and low distortion output

LMX Series – High Performance Linear AC Power Source up to 6kVA, or 30kVA option


Trust the Experts at ACA TMetrix Inc.

ACA TMetrix Inc. is a leading Canadian distributor of test and measurement instruments and design tools. For over 55 years we have provided products manufactured by the world’s leading instrument manufacturers. Leading Distributor of Design Tools and Test Equipment in Canada.

Specifications

Power Source Specifications

  • Output Frequency: 15 to 5000 Hz, Full Power
  • Line Regulation: 0.1% max for a 10% line change
  • Programmable Impedance:
    • Resistive: -100 Ohm to +100 Ohm
    • Inductive: 0 to 2 mH
  • Load Regulation:
    • 0.25% (15 to 2000 Hz)
    • 0.5% (2000 to 5000 Hz)
    • Improved to less than 0.03% with CSC engaged
  • Output Distortion (Vthd):
    • 3U Models:
      • 15~450 Hz: < 0.1%
      • 450~5000 Hz: < f x 0.076% + 0.07% (f in kHz)
    • 5U & 8U Models:
      • 45~1,000 Hz: < 0.1%
      • 1,000~5,000 Hz: < 0.25%
  • Ripple and Noise: < 50 mVrms
  • Response Time: 5µsec typical to a step load change
  • Small Signal Bandwidth: 5 Hz to 50 kHz, typical

Mechanical Specifications

  • Mounting: Standard 19-inch rack; slide rails available as an option for all models
  • Height: See model table for panel height
  • Depth: Will not exceed 24 inches from the front panel to the rear of the chassis, including connectors, handles, and cabling
  • Cooling: Forced air, front or side intakes, rear exhaust with auto fan speed control for low acoustic noise operation

LMX Controller Specifications

  • Controller Functionality: Single or three-phase AC arbitrary waveform generator and Precision AC metering system
  • Metering: Samples output volts and amps at 1024 samples per measurement using a 16-bit A/D converter
  • Interfaces: LAN, USB, IEEE 488.2, and RS232 interfaces using SCPI commands
  • Frequency: 15.00 to 5000 Hz ±0.01%
  • Voltage (Direct): Programmable, 0-VMAX, in 0.1 volt steps
  • Phase Angle: Programmable from 0-359° in 1° increments ± 0.5°
  • Current Limit: Programmable from 0 to I peak maximum of the power source; accuracy ± 0.5%, resolution ±10mA
  • Waveform Library: Stores up to 200 waveforms that can be edited and executed in any manner and in any output phase

Metering Specifications

  • Voltmeter:
    • Range: 0-340 volts L-N, 0-600 volts L-L
    • Resolution: 0.10VAC (front panel), 0.001VAC (remote interface)
    • Accuracy: ±0.1% of range
  • Ammeter:
    • Range: 100% of system current rating
    • Resolution: 0.01 Arms
    • Accuracy: ± (0.5% + f (kHz) * 0.5%) F.S.
  • Power Meter:
    • Range: Based on ammeter range
    • Resolution: 1 W, 1 VA (front panel) or 0.1 W, 0.1 VA (remote control)
    • Accuracy: ± 0.75% of Full Scale
  • Power Factor & Crest Factor: Calculated and displayed to four significant digits

 

Datasheet