Hioki Battery Tester BT3554-50 Pro Kit (TEST PRODUCT)

Hioki Battery Tester BT3554-50 Pro Kit (TEST PRODUCT)

$10.00

  • Noise reduction technology improves noise resistance
  • Screen and audio*2 guidance simplifies measurement
  • Measurement data is linked to site information and saved, reducing management man-hours
  • A variety of measurement data can be centrally managed using Hioki’s GENNECT Cross app*3
  • New protector delivers better ergonomic hold and durability in the field.
  • Instantaneously diagnose battery degradation (PASS, WARNING, FAIL) by measuring internal resistance and voltage*1
  •  Battery measurement can be performed while the battery is connected to its host device, without taking it offline
  • Measure and save data in as fast as 2 seconds, a 60% improvement from the legacy 3554

 

SKU: BT3554-50-1 Category:



Introducing the Hioki Battery Tester BT3554-50 Pro Kit (TEST PRODUCT)

Hioki portable battery testers support the maintenance of UPS and storage batteries critical to the life support of all businesses. The BT 3554-50 battery internal resistance tester sets the standard for assessing the deterioration and remaining life of UPS and other lead-acid batteries by giving a complete diagnosis via battery resistance testing. The specially designed L2020 Pin Type Lead further improves testing efficiency with an L-shaped tip that lets you reach deep into the battery racks to completely probe the terminals.

 

 

INPUT MEASUREMENT DATA AUTOMATICALLY INTO YOUR EXISTING EXCEL FORM: EXCEL® DIRECT INPUT FUNCTION

Excel® Direct Input function allows you to input measurement values directly and automatically into an Excel file once the measurement Auto-hold function is activated. You can easily input the data into an existing Excel form. (When using the Wireless Adapter Z3210)

WALL AND SHOULDER STRAPS LET YOU WORK WITH BOTH HANDS

If you’re measuring a number of batteries in a large area, use the included shoulder strap to carry the instrument with you while making measurements. Or if there are numerous batteries at a single location, use the Magnetic Strap Z5020 (sold separately) to hang the instrument on the wall while you work.

Hioki Battery Tester BT3554-50 Pro Kit (TEST PRODUCT)



Hioki Battery Tester BT3554-50 Pro Kit (TEST PRODUCT)

Key Features

  • Noise reduction technology improves noise resistance
  • Screen and audio*2 guidance simplifies measurement
  • Measurement data is linked to site information and saved, reducing management man-hours
  • A variety of measurement data can be centrally managed using Hioki’s GENNECT Cross app*3
  • New protector delivers better ergonomic hold and durability in the field.
  • Instantaneously diagnose battery degradation (PASS, WARNING, FAIL) by measuring internal resistance and voltage*1
  •  Battery measurement can be performed while the battery is connected to its host device, without taking it offline
  • Measure and save data in as fast as 2 seconds, a 60% improvement from the legacy 3554

*1: The thresholds for determining the pass/fail condition of a battery depends on the specifications and standards of the battery manufacturer, battery type, capacity, etc. It is important and necessary to always conduct battery testing against the internal resistance and terminal voltage of a new or reference battery. In some cases, it may be difficult to determine the deterioration state of traditional open type (liquid) lead-acid or alkaline batteries which demonstrate smaller changes in internal resistance than sealed lead acid batteries.
*2: Audio generated by Bluetooth®-connected device.
*3: Data can be downloaded to tablets and smartphones using Hioki’s dedicated apps available from the Google Play or App Store. (When using the Z3210)

HOW TO USE BATTERY TESTERS: OBSERVING MEASUREMENT RESULTS CAPTURED WIRELESSLY ON A MOBILE DEVICE

Measured values captured by the Hioki BT3554-50 Battery Tester with Bluetooth wireless technology can be displayed and saved onto a mobile device wirelessly. (When using the Wireless Adapter Z3210) The results can also be used to create automatic reports. Simply install the free GENNECT Cross app onto your mobile device and connect to the Hioki BT3554-50. Reports created on your mobile device can even be e-mailed to the office to further increase work efficiency. Data uploaded by the Gennect Cross app can also be loaded into a PC to view the historical state of the specified battery as a graph.



Key Benefits

ACCURATELY ASSESS LEAD-ACID BATTERY DETERIORATION USING PROPRIETARY TECHNOLOGY

The new Battery Tester BT3554-50 sets a new standard for UPS and lead-acid battery diagnostics. Since the battery’s internal resistance and voltage are measured using the impedance method, diagnostics can be performed while the battery is connected to its host device, without taking it offline. Proprietary noise reduction technology allows more accurate measurement, even in noisy environments.

ENJOY MEASUREMENT GUIDANCE AND EASY DATA MANAGEMENT FUNCTIONALITY WITH THE LATEST SOFTWARE

When the BT3554-50 is paired with a dedicated mobile app (GENNECT Cross), the mobile device will provide audio guidance announcing the next battery number to be measured. This feature helps prevent erroneous measurements. You can also set up measurement locations information and battery numbers in advance to create profiles to which measurement data and diagnostic results will be linked. This capability simplifies data management, even when performing diagnostic work on large numbers of batteries.

GENERATING COMPARATIVE JUDGMENTS BASED ON A LEAD-ACID BATTERY’S INTERNAL RESISTANCE AND VOLTAGE

By using its comparator function to simultaneously measure the internal resistance and voltage of a lead-acid, nickel-cadmium, or nickel-hydride battery, the BT3554-50 can generate comparative judgments quantifying degradation of the cell based on user-specified threshold values. Furthermore, voltage sign detection facilitates instantaneous determination of whether batteries have been connected properly in newly installed UPS systems.

SAVING DATA EASILY JUST BY PLACING THE LEADS IN CONTACT WITH A BATTERY’S TERMINALS

The BT3554-50 auto-hold function automatically holds measured values once they stabilize. The instrument’s auto-memory function, which automatically stores measured values resulting from the auto-hold function in its internal memory, further streamlines work tasks.

NEW LEADS FOR MORE CONVENIENT MEASUREMENT IN DISTRIBUTION PANELS AND OTHER CONFINED LOCATIONS

The Pin Type Lead L2020 with L-shaped tips is available as a new option. The design significantly improves ease of use when inspecting batteries installed in confined locations.

APPLICATIONS: MANAGE OTHER UPS INSPECTION DATA TOGETHER

GENNECT can serve as a central repository for managing data from Hioki clamp meters and other instruments. Example: UPS inspection 1.UPS system ACV measurement (CM4372, CM4374) 2.DCV measurement (CM4372, CM4374) 3.AC/DC current measurement (CM4372, CM4374) 4.Ripple current measurement (CM4002) 5.Battery degradation diagnostics (BT3554-50) 6.Measurement site photograph

 


Hioki Battery Tester BT3554-50 Pro Kit (TEST PRODUCT)


Trust the Experts at ACA TMetrix Inc.

ACA TMetrix Inc. is a leading Canadian distributor of test and measurement instruments and design tools. For over 55 years we have provided products manufactured by the world’s leading instrument manufacturers. Leading Distributor of Design Tools and Test Equipment in Canada.

Specifications

Resistance measurement range 3 mΩ (max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (max. display 3.100 Ω, resolution 1 mΩ), 4 ranges
Accuracy: ±0.8 % rdg ±6 dgt (3 mΩ range: ±1.0 % rdg ±8 dgt)
Testing source frequency: 1 kHz ±30 Hz
With function for avoiding noise frequency enabled: 1 kHz ±80 Hz
Testing current: 160 mA (3m/30 mΩ range), 16 mA (300 mΩ range), 1.6 mA (3 Ω range)
Open terminal Voltage: 5 V peak
Voltage measurement range ± 6 V (max. display ±6.000 V, resolution: 1 mV) to ± 60 V (max. display ±60.00 V, resolution: 10 mV), 2 ranges, Accuracy: ±0.08 % rdg ±6 dgt
Temperature measurement accuracy Measurement range: -10°C to 60°C (14°F to 140°F), Maximum display: 60.0°C (140.0°F), Resolution 0.1°C (0.1°F), Measurement accuracy*: ±1.0°C (±1.8°F)
* When using the Clip Type Lead with Temperature Sensor 9460.
* When using the Temperature Probe 9451, add ±0.5°C (±0.9°F) (cable length: 1.5 m [59.1″]).
* When using the Temperature Probe 9451S, add ±0.5°C (±0.9°F) (cable length: 0.1 m [3.94″]).
BT3554-50 standalone accuracy with simulated input: ±0.5°C (±0.9°F)
Absolute max. input voltage 60 V DC max. (No AC input)
Measurement time 100 ms
Response time Approx. 1.6 sec.
Comparator Compares measured values with set threshold values to make judgments and reports them to the user.
Judgment notification method: Results are displayed as shown below (segment) and beeping tones sound
When the Voltage value (high): Resistance value (low)= PASS, Resistance value (medium)= WARNING, Resistance value (high)= FAIL
When the Voltage value (low): Resistance value (low)= WARNING, Resistance value (medium)= WARNING, Resistance value (high)= FAIL
If the judgment result is WARNING or FAIL, the audio tone is accompanied by a red backlight.
User-selectable voltage judgment method: ABS (absolute value judgment), POL (polarity judgment )
Savable settings: 200 tables
Memory functionality Operation: Save, load, and delete measurement data, Save and delete profile information, Number of data sets: 6000, Memory architecture: 500 data sets per unit (12 units)
Saved data: Saved measurement data is linked to profile information.1. Measurement data: Data can be saved, loaded, and deleted by operating the instrument.
-1. Date and time
-2. Resistance value, voltage value, and temperature
-3. Comparator threshold value and judgment result2. Profile information: Profile information can be saved, loaded, and deleted using a supported application (GENNECT Cross or GENNECT One).
-1. Profile numbers: 1 to 100 (Data (2), (3), and (4) below are saved for each profile number)
-2. Location: User-defined comment such as location of UPS
-3. Device information: User-defined comment such as UPS management number
-4. Battery number: 1 to 500 (start number, end number)
Measurement Navigator Operation: Announces the next battery number to be measured via a screen display and audio guidance.
Audio output is generated by a connected mobile device when using the Z3210 and a supported application (GENNECT Cross).
Preparations: Profile information that’s been registered with a supported application (GENNECT Cross or GENNECT One) must be transferred to the instrument.
Communication interface USB
Bluetooth® wireless communications (when Z3210 installed)
Other functions Temperature measurement (-10.0 to 60.0 °C), Zero-adjustment, Hold, Auto-hold, Auto-memory, Auto-power-save, Clock
Power supply LR6 (AA) Alkaline dry battery ×8
Continuous operating time: About 8.3 hr. (without Z3210 installed), About 8.2 hr. (with Z3210 installed and wireless communications active)
Dimensions and mass 199 mm (7.83 in)W × 132 mm (5.20 in)H × 60.6 mm (2.39 in)D (with protector), 960 g (33.9 oz) (including batteries and protector)
Accessories Carrying Case C1014 ×1, Protector Z5041 ×1, Fuse Set Z5050 ×1, 0 Adj Board ×1, Neck strap ×1, USB cable ×1, Application software CD (GENNECT One) ×1, AA alkaline battery (LR6) ×8, User Manual ×1

 

Datasheet


Get in touch with us to inquire about our tailored consulting services.