POWER ANALYZER 3390

POWER ANALYZER 3390

$9,595.00

DC, 0.5 Hz to 150 kHz, 3-phase 4-wire, High Precision Power Analyzer for Motor and Inverter Efficiency Analysis

 

REQUEST A QUOTE



Description

Hioki benchtop power meters and power analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The 3390 is a high-precision, broad-range power analyzer for measuring electrical power from DC to inverter frequencies, providing four input channels to support single- and three-phase inverter motor system measurements. POWER

3390 main unit, clamp sensor is sold separately

CERS232CLANUSB2TrueRMS

Key Features

• Advanced motor analysis functions (measures the electric angle and supports vector control)

• High-speed harmonic analysis function (50 ms data refresh rate)

• Noise analysis function for inverters (using FFT analysis technology)

• Inverter power measurement with the convenience of clamp on sensors

• Achieve the same superior accuracy as direct wiring method meters at maximum ±0.16% (when combined with the 9709)

• LAN, USB, and CF card – a rich array of interfaces

■ Basic specifications (Accuracy guaranteed for 6 months, Post-adjustment accuracy guaranteed for 6 months)

 

Measurement line type

 

Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire, Voltage 4 channels, Current 4 channels, Isolated between each channel

 

Measurement items

 

Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire, Voltage 4 channels, Current 4 channels, Isolated between each channel

 

Noise measurement (FFT processing): RMS spectrum of voltage/current
Harmonic measurement: RMS value, Content factor, Phase angle, Total distortion, Disequilibrium factor

 

Additional functions (With optional 9791 or 9793 installed in the main unit) : Torque, Rotation, Frequency, Slip, or Motor output

 

Harmonic measurement

 

Input: 4 ch, Synchronization frequency range: 0.5 Hz to 5 kHz,
Number of harmonic orders: Max. 100th order

 

Noise measurement

 

Number of channels: 1 ch (select one channel from CH1 to CH4),
Maximum analysis frequency: 100 k/ 50 k/ 20 k/ 10 k/ 5 k/ 2 kHz

 

Measurement range

 

Voltage range: 15 to 1500 V, 7 ranges
Current range: 400 mA to 500 A (depends on current sensor, 20A/ 50A/ 200A/ or 500A rated)
Power range: 6.0000 W to 2.2500 MW (depends on combination of voltage and current range)
Frequency range: 0.5 Hz to 5 kHz

 

Basic accuracy

 

Voltage: ±0.05 % rdg. ±0.05 % f.s.
Current: ±0.05 % rdg. ±0.05 % f.s. + current sensor accuracy
Active power: ±0.05 % rdg. ±0.05 % f.s. + current sensor accuracy

 

Synchronization frequency range

 

0.5 Hz to 5 kHz

 

Frequency band

 

DC, 0.5 Hz to 150 kHz

 

Data update rate

 

50 ms (For harmonic measurement, depends on the synchronization frequency when less than 45 Hz)

 

Display refresh rate

 

200 ms (Independent of internal data update rate; waveform and FFT depend on the screen)

 

Data save interval

 

OFF, 50 msec to 500 msec, 1 sec to 30 sec, 1 minute to 60 minutes, 15 settings

 

External interfaces

 

vLAN, USB (communication/ memory), RS-232C, CF card, Synchronization control

 

Power supply

 

LAN, USB (communication/ memory), RS-232C, CF card, Synchronization control

 

Dimensions and mass

 

340 mm (13.39 in) W × 170 mm (6.69 in) H × 157 mm (6.18 in) D, 4.8 kg (169.3 oz)

 

Accessories

 

Instruction Manual ×1, Power cord ×1, Measurement Guide ×1, USB cable ×1, Input cord label ×2, D-sub connector × 1 (when 9792 or 9793 is installed)

■ Specifications for the motor testing option (Accuracy guaranteed for 6 months, Post-adjustment accuracy guaranteed for 6 months)

 

Number of input channels

 

3 channels, CH A: Torque signal input (DC V / Frequency input), CH B: Rotation signal input (DC V / Pulse input), CH Z: Z-phase signal input (Pulse input)

 

Measurement item

 

Voltage, Torque, Rotation, Frequency, Slip, Motor power

 

DC V (CH A B)

 

Measurement range: ±1 V/ ±5 V/ ±10 V, Accuracy: ±0.1 % rdg. ±0.1 % f.s.

 

Frequency (CH A)

 

Effective amplitude range: ±5 V peak, Measurement band: 1 kHz to 100 kHz

 

Pulse (CH B)

 

Detection level: (Low) 0.5 V or less, (High) 2.0 V or more, Measurement band: 1 Hz to 200 kHz

 

Pulse (CH Z)

 

Detection level: (Low) 0.5 V or less, (High) 2.0 V or more, Measurement band: 0.1 Hz to 1 kHz

Get in touch with us to inquire about our tailored consulting services.