POWER METER PW 3336-03

POWER METER PW 3336-03

$4,395.00

2-Channel AC/DC Power Meter for Single-Phase to 3P3W Equipment such as Motors, Inverters, Power Conditioners, and Power Supplies with GP-IB, D/A output installed model

REQUEST A QUOTE
SKU: PW3336-03 Category:



Description

Hioki benchtop power meters and power analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The PW3336 series measure power on the full range of electrical equipment, from single-phase devices such as battery-driven devices and household electronics to industrial use and three-phase electrical equipment over 2 input channels. The power meters provide coverage from DC to inverter frequencies with support for voltages up to 1000 V and direct-input currents of up to 65 A, and can also measure currents of up to 5000 A using an optional current sensor. POWER METER PW

Order Code

PW3336 2ch model
PW3336-01 2ch, GP-IB installed model
PW3336-02 2ch, D/A output installed model
PW3336-03 2ch, GP-IB, D/A output installed model

LAN                                                                                                                            GPIBPW3336-01/-03RS232CCETrueRMS

Key Features POWER METER PW

• Can measure DC, and single-phase 2-wire to 3-phase 3-wire with 2-channels input

• For development and production of motors, inverters, power conditioners, power supplies, and other devices

• High-precision basic accuracy ±0.1 % (*1) (*1) For complete details, please refer to the specifications

• Wide frequency bandwidth of 0.1 Hz to 100 kHz or DC

• High-current measurement up to 65 A direct input

• Harmonic measurement up to the 50th order with IEC 61000-4-7 compliant

• High-accuracy measurement, even with a low power factor for no-load testing of transformers and motors

• Built-in external sensor input terminals for measure up to 5000 A AC

• Synchronize up to 8 units for multi-units measurement

■ Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 6 months)

 

Measurement lines

 

Single-phase 2-wires, single-phase 3-wires, 3-phase 3-wires, (voltage / current measurement range set for each wiring mode)

 

Measurement items

 

Voltage, Current, Active power, Apparent power, Reactive power, Power factor, Phase angle, Frequency, Efficiency, Current integration, Active power integration, Integrated time, Voltage waveform peak value, Current waveform peak value, Voltage crest factor, Current crest factor, Time average current, Time average active power, Voltage ripple factor, Current ripple factor

 

Harmonic parameters

 

Synchronization frequency range: 10 Hz to 640 Hz, Analysis order up to 50th
Harmonic voltage RMS value, Harmonic current RMS value, Harmonic active power, Total harmonic voltage distortion, Total harmonic current distortion, Voltage fundamental waveform, Current fundamental waveform, Active power fundamental waveform, Apparent power fundamental waveform, Reactive power fundamental waveform, Power factor fundamental waveform (displacement power factor), Voltage current phase difference fundamental waveform, Interchannel voltage fundamental wave phase difference, Interchannel current fundamental wave phase difference, Harmonic voltage content % , Harmonic current content % , Harmonic active power content %
(The following parameters can be downloaded as data during PC communication but not displayed: Harmonic voltage phase angle, Harmonic current phase angle, Harmonic voltage current phase difference)

 

Measurement range

 

Voltage : AC/DC 15 V to 1000 V, 7 ranges
Current : AC/DC 200 mA to 50 A, 8 ranges
Power : 3.0000 W to 100.00 kW (Depends on combination of voltage and current range)

 

Integration measurement (Integration time up to 10,000 hours)

 

[Current] No.of displayed digits: 6 digits (from 0.00000 mAh, Polarity-independent integration and Sum value)
[Active power] No.of displayed digits: 6 digits (from 0.00000 mWh, Polarity-independent integration and Sum value)

 

Input resistance (50/60 Hz)

 

[Voltage] 2 MΩ, [Current] 1 mΩ or less (direct input)

 

Basic accuracy (Active power)

 

±0.1% rdg. ±0.1% f.s. (DC)
±0.1% rdg. ±0.05% f.s. (45 Hz to 66 Hz, at Input < 50% f.s.)
±0.15% rdg. (45 Hz to 66 Hz, at 50% f.s. ≤ Input)

 

Display refresh rate

 

5 times/s to 20 seconds (depend on average times settings)

 

Frequency characteristics

 

DC, 0.1 Hz to 100 kHz

 

D/A output (-02/-03 model only)

 

16 channels (selectable from following items), Level output DC ±2 V, Waveform output 1 V f.s.
Level output, instantaneous waveform output (voltage, current, active power)
Level output (apparent power, reactive power, power factor, or other)
High-speed active power level output

 

Functions

 

[Rectification method] AC+DC, AC+DC Umn, AC, DC, FND, Auto-range, Average, VT or CT ratio settings, Synchronized control, MAX/MIN, or other functions

 

Interfaces

 

RS-232C / LAN standard, (-01/-03 model also includes GP-IB)

 

Power supply

 

100 to 240 V AC, 50/60 Hz, 40 VA max.

 

Dimensions and mass

 

305 mm (12.01 in) W × 132 mm (5.20 in) H × 256 mm (10.08 in) D, 5.2 kg (183.4 oz)

 

Accessories

 

Instruction manual ×1, Measurement guide ×1, Power cord ×1

Catalogs

pdf

PW3337E5-56E

Get in touch with us to inquire about our tailored consulting services.