1 800 665 7301 | info@tmetrix.com

    • Easily create tasks
    • Obtain fast results
    • Adapts to the user’s needs and skills level
    • Reduces working time
    • Saves money!
    • Designed to operate with maximum intelligence
    • Automates workflows
    • Enables autonomous measurements

     

  • Robust RF Test on PCB and Ceramic

    • Replace costly and inflexible test fixtures with easy-to-use probe tips
    • Long lifetime – typically over 1,000,000 contacts
    • GS/SG footprint up to 4 GHz and GSG up to 20 GHz
    • High-power RF test: up to 30 Watts
    • Test at temperatures from -60°C to 200°C

     

  • High power, High performance probe

    • High power – 66 W at 2.4 GHz and 43 W at 5 GHz
    • Extremely low insertion loss of ≤ 0.4 dB (typical) up to 40 GHz
    • Excellent contact control and low contact resistance
    • High performance on any pad material (Al or Au)
    • Longest lifetime – typically one million (1,000,000) touchdowns

     

  • Excellent Performance – Longest Lifetime

    • Best price per contact – typically over one million (1,000,000) touchdowns
    • RF/Microwave signal is shielded and completely air isolated in the probe body
    • Excellent performance in vacuum environments and temperatures as low as 4 K, or as high as 300°C
    • Highest impedance control with perfectly-symmetrical, MEMS-machined coplanar contact structure
    • Probe on any pad material with minimal damage

     

    • Highest accuracy in test results
    • Easy setup even for less experienced users
    • Minimized coupling losses with minimal trench dimensions
    • Exclusive FormFactor-developed automated test methodology
    • Wide range of tools for capturing, logging and interpreting data
    • Enables hands-free autonomous calibration and re-calibration at multiple temperatures
    • Search First Light feature enables automated determination of initial position for optimization
    • Once aligned, all calibration functions are automated and performed through SiPh-Tool

     

  • Key Performance Capabilities:

    • Slew rates up to 60 V/µsec.
    • Up to 240A DC at +50VDC or –50VDC (4301-240 configuration).
    • Can provide pulses of up to 800 amps at voltages of up to ±100V (4301-240 configuration).
    • Adjustable compensation allows the system to maintain a 50V/2 µsec rise-time over a wide range of current outputs.

     

  • Key Performance Capabilities:

    • Bandwidth: DC to 50 kHz
    • Voltage: 0 to 250 VRMS; 0 to 350 VDC
    • Current: 100 to 500 ARMS
    • Distortion: 0.1%
    • Power: 4 kW to 20 kW*Power levels up to 5X rated power when driving reactive loads
    • High power efficiency and density

    *Models available with output from 4 kW to 20 kW (capable of up to 125 kVA).

     

  • Key Performance Capabilities:

    • 4-Quadrant – Can source and sink current
    • ±80V – DC supply for 12V to 48V systems; meets 80V surge requirements
    • 300 kHz Sine – DC ripple tests for all major standards
    • 3µs Rise Time – Exceeds surge and dropout slew rate requirements
    • 3mΩ DC Source Impedance – Out-performs ISO 7637-2 requirements
    • Supports ground reference and supply offset testing required for ISO 16750-2 Sect. 4.8 and other similar standards

     

  • Key Performance Capabilities:

    • Up to 900 watts RMS power output (7136 model)
    • Small signal response up to 400 kHz
    • User-adjustable precision DC offset
    • User-adjustable current limit: 1A to 25A
    • 4-quadrant operation
    • AC/DC coupled

     

  • Key Performance Capabilities:

    • Up to 900 watts RMS power output (7136 model)
    • Small signal response up to 400 kHz
    • User-adjustable precision DC offset
    • User-adjustable current limit: 1A to 25A
    • 4-quadrant operation
    • AC/DC coupled

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +12 to -12 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510 MCOR12 Power Modules are identical and interchangeable.
    • Has two high-precision measurements of output current;
      • one is used to close the regulation control loop,
      • provides an independent monitoring signal to the Crate Interface Card.
    • Fault sensing circuitry in the module sets a Fault Latch which inhibits the output.
    • A (momentary) Sync input signal inhibits MOSFET switching when it is active (high);
      • this eliminate switching noise .
      • reduces power line noise during sensitive analog signal measurements.

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +30 to -30 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510R30 MCOR30 Power Modules are identical and interchangeable
      • Programming Card is plugged into the replacement module.
    • Each channel has a critically-damped, LC noise filter with a cut-off frequency of about 8 kHz.
    • A 16-pin front panel diagnostics connector taps onto major circuit nodes which enables quick “inthe-crate” fault evaluation

     

    • 2U Chassis – 19″ rack mount 3.48” Height, 9.60” Depth and Weight 6lb.
    • Power 120V AC 60Hz
    • Washable front removable air filter
    • Ball Bearing AC fans provide 330 CFM
    • Dual plenum design
    • Cooling for 160mm,220mm depth modules
    • Diverts lower warmed air to rear of Cabinet
    • RM option diverts lower air to front of Cabinet

     

    • accommodate these control schemes
    • total control system interface on a single VME-standard card
    • occupies the left-most slot of the crate
    • monitoring voltage reference inputs, output voltages and fault conditions
    • standard VMEbus-compatible 6U by 220 mm board installed
    • Eurocard crate
    • Two 96-pin I/O connectors

     

  • MCOR Modules

    MCOR 2/6/9/12

    Each module can be customized to provide maximum outputs of 2 amps, 6 amps, 9 amps, and 12 amps. Up to 16 of these can fit in a single 6U VME style crate.

    MCOR 30

    Each module can provide a maximum output 30 amps. Up to 8 of these can fit in a single 6U VME style crate.

    • On-wafer power device characterization up to 10,000 V DC / 600 A
    • Reduced probe and device destruction at high currents up to 20 A DC and 300 A pulse
    • Prevent thin wafers from curling and breaking
    • Accurate Rds(on) measurement at high current
    • Accurate UIS measurements at high temperature
    • Roll-out stage for full wafer access and easy wafer loading/unloading
    • Seamless integration between Velox and analyzers/measurement software
    • High-throughput wafer autoloading (standard, thinned, warped, TAIKO)
    • Easy on-screen navigation, wafer mapping, and operation of accessories with Velox