1 800 665 7301 | info@tmetrix.com

    • Customizable & savable test setups
    • Program & Datalog Storage
    • User Defined Temperature Limits
    • Local & Remote Operations
    • LabView™ drivers
    • IEEE-488, RS232 ports

     

     

    • 20 Amp Operation: Full performance with 20 amp service
    • Automatic Power Reduction: Reduces power usage during idle periods
    • Heat Only Mode: Reduces power usage when cold temperatures are not used
    • WhisperStream Technology: quieter, smooth-sounding operation, 56 dBA
    • Frost Free Test Environment: dry air purge for tester interface, prevents condensation:
      0.5 to 3scfm (0.25 to 1.5 l/s)
    • Heated Defrost: quickly removes moisture buildup from internal chiller
    • DUT Temperature Control : Proprietary control algorithm enables DUT temperature to be directly controlled
    • Transition Rate*
      -55 to +125°C, approx. 10 seconds
      125 to -55°C, approx. 10 seconds
    • System Airflow Output*
      4 to 18scfm (1.9 to 8.5 l/s) Continuous
    • Temperature Range*
      -80 to +225°C (60Hz) No LN2 or LCO2 Required

     

    • High reliability thermal cycling without thermoelectric modules
    • Temperature range: -65 to 175°C
    • Cooling power:
      • 40W at -40°C for lower power devices
      • 55W at -55°C and 120W at -40°C.
    • Transition rate: up to <35 sec over 25 to -40°C
    • Easy and secure thermal connection to in-circuit or test socked DUT
    • Touch-screen controller: user-programmable temperatures, graphing, data logging
    • Communications options: Ethernet, USB, IEEE, RS232

     

  • -60° to +200°C

    • Economy model with high thermal capacity
    • Precise temperatures with fast transitions from -60 to 200°C
    • No annual leak testing required per EU 517/2014 F-Gas Regulation
    • Effective testing and conditioning of electronic components, boards, and modules
    • Available for 50 and 60Hz operation
    • No need for Liquid Nitrogen (LN2) or Liquid Carbon Dioxide (LCO2)
    • Remote communications and set up and touch screen operation
    • User Defined Temperature Limits

     

     

  • The new G5.RSS series features

    • High control dynamics
    • An exceptional accuracy
    • A nominal output voltage of up to 3000 VDC
    • A wide current-voltage range with an auto-ranging factor of 3.
    • You get the best value for your investment.

     

    • Dynamic set up: During a simple frame reading, users can define elements to be acquired, recorded, visualized and surveyed in real time.
    •  Macro-command: Users can write and execute complex test sequences thanks to macro-command functions.
    •  Local & Distant Integration: AT-DIAG can be driven and interrogated by external software. It can also be used with a computer through Ethernet.
    • Communication ports: Communication is done through RS232, NI CAN acq. Card, specific acquisition card or system.
    •  Protocols: FREERUNNING, KWP2000, CAN, LIN, FlexRay, ARINC, … Possibility to implement new protocols (customized protocol, …).
    •  Multi-product & Multi-protocol Communication: Communication can be set up with multiple addresses and protocols during a single test.

     

    • 1 software for all your equipment
    • 1 software for all standards
    • 1 software for your electrical and EMC tests
    • Advanced functions of monitoring and control
    • Automated reports
    • Team of specialists at your disposal

     

    • Fast: ACA compression and parallelization allow to speed up the calculation
    • Accurate: Fully validated with measurement results on real mock-up
    • Innovative: New method from research labs
    • Powerful: Compute very large models
    • Easy: Dedicated graphical user interface with modern layout

     

    • Fast: ACA compression and parallelization allow to speed up the calculation
    • Accurate: Fully validated with measurement results on real mock-up
    • Innovative: New method from research labs
    • Powerful: Compute very large models
    • Easy: Dedicated graphical user interface with modern layout

     

    • Unique user interface for all tests
    • Independent from any measuring device manufacturers
    • Free drivers and over 500 supported devices
    • Efficient and dedicated Technical support
    • Wide range of supported standards (ENxx, CISPR, AUTOMOTIVE, DO160, …)
    • Interface Agilent VEE™, WindowsLabView™, LabWindows CVI™, Visual C++
    • Operating system: Win XP, Vista, Seven, Windows 8
    • Report in MS Office™ 2003, 2007, 2010, 2013, Open office

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Bidirectional (source & sink), Regenerative 0…65VDC to 0…1500VDC, 20kW up to 1.5 MW 

    • cell system nominal voltage and type of chemistry
    • number of cells
    • internal resistance and associated parameters
    • cell temperature progression
    • allowed current
    • charge efficiency
    • energy computing and management facilities
    • time-dependent and functional dependent parameters

     

    • Setting of operational parameters for each output phase: (frequency, phase, voltage, basic waveform)
    • Defining functional blocks enabling a wide variety of modulation capabilities
    • Defining, editing and storing of even complex and long test sequences
    • Preview window for output voltage waveforms
    • LC load mode, definition of complex equivalent circuits
    • Hand drawing curve tool and FOURIER tool (harmonics synthesis)
    • TC.ACS provides an extensive safety concept in order to detect unwanted or off-limit conditions very quickly and to initiate controlled limiting or even a shutdown.

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Photovoltaic applications, the quality and technical data of the AC-DC converter is of primary interest. Solar installations are intended for a lifetime of roughly 20 years, therefore even fractions of a percent in efficiency will represent significant amounts of energy losses.

  • Programmable Grid-tie Sink High-Power DC Supply,