HIOKI Clamp On Power Meters are multi-channel power measuring devices utilizing clamp sensor input to accurately and safely measure power on single-phase to three-phase lines. The PW3365-20 takes safety and convenience one step further by being the world’s first non-metallic contact power meter that utilizes completely covered voltage clips that can be attached to any part of a cable or busbar. Customers can now monitor power demand and other power parameters to aid in energy audits and validate energy saving measures without risk of short-circuit accidents, power interruptions, or bodily injury due to electrocutions.  CLAMP ON POWER LOGGER PW3365

 

PW3365-20

 

Power Logger (w/4 PW9020 Non Contact Voltage Sensors)

 

PW3365-20-01/100

 

Power Logger Kit (Custom 100A Kit)

 

PW3365-20-01/500

 

Power Logger Kit (Custom 500A Kit)

 

PW3365-20-01/1000

 

Power Demand Analyzer (Custom 1000A Kit)

 

PW3365-20-01/5000

 

Power Demand Analyzer (Custom 5000A Kit)

 

Note: Clamp On Power Logger PW3365 by itself does not support current and power measurements. Current and power measurements require clamp on sensors, sold separately. Use only HIOKI SD cards guaranteed to work for saving measurement data (options, sold separately).

予備CELANUSB2TrueRMSSD

 

Key Features

• The PW3365’s dedicated voltage sensor delivers the world’s first no-metal-contact measurement.

• Supports single to three-phase, 4-wire circuits

• Measure between 90V to 520V

• Slim, compact design that can be placed anywhere

• Store months of data on SD cards

• The QUICK SET function guides you in making the right connections

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 6 months)

 

Measurement line & number of circuits

 

50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels

 

Measurement items

 

Voltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power, apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand

 

Voltage ranges

 

400 V AC (Effective measurement range: 90.0 V to 520.0 V)

 

Current ranges

5

00.00 mA to 5.0000 kA AC (depends on current sensor in use),
50.000 mA to 5.0000 A AC (Leak clamp on sensor only)

 

Power ranges

 

200.00 W to 6.0000 MW (Depends on voltage/current combination and measured line type)

 

Basic accuracy

 

Voltage : ±1.5% rdg. ±0.2% f.s(combined accuracy with PW3365-20 + PW9020)
Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy
Active power : ±2.0% rdg. ±0.3% f.s. + clamp sensor accuracy (at power factor = 1)

 

Display update rate

 

0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication)

 

Save destination

 

SD Memory card, or internal memory at real time

 

Data save interval

 

1 sec to 30 sec, 1 minute to 60 minutes, 14 selections

 

Save items

 

Measurement value save: Average only / Average, Maximum, Minimum value
Screen copy: BMP form (saved every 5 min. at minimum interval time)
Waveform save: Binary waveform data

 

Interfaces

 

SD memory card
HTTP server function, remote settings via communication program, data download
USB 2.0: When connected to a PC, the SD Card and internal memory are recognized as removable storage devices, remote settings via communication program, data download
Pulse output: proportional to active power consumption when measuring integral power consumption, Isolated open-collector signal

 

Functions

 

Connection check, Quick Set navigation guide, clock

 

Power supply

 

AC adapter Z1008: (100 to 240 V AC, 50/60 Hz), 45 VA (including AC adapter)
Battery pack 9459: (DC 7.2 V, 3 VA, charging time 6 hr 10 m), 5 hours of continuous use (with back light off)

 

Dimensions and mass

 

180 mm (7.09 in)W × 100 mm (3.94 in)H × 48 mm (1.89 in)D, 540 g (19 oz) without PW9002
180 mm (7.09 in)W × 100 mm (3.94 in)H × 68 mm (2.68 in)D, 820 g (28.9 oz) with PW9002

 

Accessories

 

Safety Voltage Sensor PW9020 ×1 set, AC adapter Z1008 ×1, USB cable ×1, Instruction manual ×1, Measurement guide ×1, Color spiral tubes ×1 set: red, yellow, blue/four each, Spiral tubes for grouping clamp sensor cords ×10