POWER QUALITY ANALYZER 3197

POWER QUALITY ANALYZER 3197

3-Phase 4-Wire Portable Power Quality Analyzer to Detect, Measure and Record Power Quality Issues, Harmonics, Demand, Inrush and Power Transients

 

REQUEST A QUOTE



Description

Hioki portable power meters and analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The 3197 is a handheld power quality analyzer for monitoring and recording power supply anomalies, allowing their causes to be quickly investigated. POWER QUALITY ANALYZER 3197

3197 main unit only

Note: Optional current sensor is necessary to measure current or power parameters.

CETrueRMSUSB2

Key Features

• Single-phase 2-wire/single-phase 3-wire/three-phase 3-wire/three-phase 4-wire

• Catch power quality problems on the fly, before they catch you

• Record measurement data on internal memory for easy transfer to a PC via USB

• Analyze measurement data on a bundled PC aplication software

■ Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

 

Measurement line type

 

Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire

 

Measurement range

 

[Voltage] 600.0 V AC, [Current] 500.0 mA to 5.000 kA AC (depends on current sensor in use),
[Power] 300.0 W to 9.00 MW (depends on combination of current range and line type)

 

Basic accuracy

 

Voltage: ±0.3 % rdg. ±0.2 % f.s.
Current: ±0.3 % rdg. ±0.2 % f.s. + current sensor accuracy
Active power: ±0.3 % rdg. ±0.2 % f.s. + current sensor accuracy (at power factor=1)

 

Measurement items

 

1. RMS Voltage and Current (200 ms calculation)
2. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle
3. Current (1/2) RMS: half-cycle calculation
4. Frequency
5. Active Power/ Reactive Power/ Apparent Power/ Power Factor/ Displacement Power Factor/ Active or Reactive Energy Consumption
6. Demand (Active or Reactive power)
7. Up to 50th Harmonic Analysis (Time series measurement or recording is not available)
8. Peak Voltage and Current
9. Total harmonic voltage distortion ratio
10. Voltage Unbalance Factor
11. K Factor (Time series recording is not capable)
12. Total harmonic current distortion ratio (Time series recording is not available)

 

Event Detection

 

1. Voltage Swells (Rise), Voltage Dips (Drop), Interruptions: RMS value detected using voltage (1/2) measured every half cycle
2. Inrush Current: RMS value detected using current (1/2) every half cycle
3. Transient Overvoltage: 50 Vrms or more detection, 10 to 100 kHz
4. Timer: Detect events at preset intervals
5. Manual: Detect events when keys are pressed

 

Number of Recordable Events

 

50 event waveforms, 20 event voltage fluctuation graphs, 1 inrush current graph, 1000 event counts

 

Interfaces

 

USB 2.0 (Communication with the PC)

 

Display

 

4.7-inch color STN LCD

 

Power supply

 

AC adapter 9418-15 (100 – 240 V, 50/60 Hz), Battery pack 9459, Continuous use 6 hr (LCD Back-light auto-OFF 5 min.), 23 VA max.

 

Dimensions and mass

 

128 mm (5.04 in)W × 246 mm (9.69 in)H × 63 mm (2.48 in)D, 1.2 kg (42.3 oz) (with Battery pack)

 

Accessories

 

Voltage cord L9438-55 ×1 (Black ×4), AC adapter 9418-15 ×1, Power cord ×1, Battery pack 9459 ×1, Input terminal labels ×1, Input cord labels ×1, Strap ×1, Instruction manual ×1, Measurement guide ×1, USB Cable ×1, CD-R (Applications software) ×1, Carrying case ×1