    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +30 to -30 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510R30 MCOR30 Power Modules are identical and interchangeable
      • Programming Card is plugged into the replacement module.
    • Each channel has a critically-damped, LC noise filter with a cut-off frequency of about 8 kHz.
    • A 16-pin front panel diagnostics connector taps onto major circuit nodes which enables quick “inthe-crate” fault evaluation

     

  • Enabling single-contact high-current/high-voltage test

    • Enables coaxial measurements up to 10,000 V and 300 A pulsed (600 A in a parallel configuration) with a single touchdown
    • Even distribution of high current with innovative multi-fingertip design
    • Compatible with Tesla 200/300 mm power device characterization system
    • Reduced measurement time by testing both high-voltage and high-current conditions with a single touchdown
    • Accurate characterization of a wide range of pad sizes and test currents, with minimum pad damage and contact resistance
    • Safe, reliable and repeatable high-current/voltage measurements over a wide temperature range (from -55°C to +300°C)

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Bidirectional (source & sink), Regenerative 0…65VDC to 0…1500VDC, 20kW up to 1.5 MW 

    • cell system nominal voltage and type of chemistry
    • number of cells
    • internal resistance and associated parameters
    • cell temperature progression
    • allowed current
    • charge efficiency
    • energy computing and management facilities
    • time-dependent and functional dependent parameters

     

    • Setting of operational parameters for each output phase: (frequency, phase, voltage, basic waveform)
    • Defining functional blocks enabling a wide variety of modulation capabilities
    • Defining, editing and storing of even complex and long test sequences
    • Preview window for output voltage waveforms
    • LC load mode, definition of complex equivalent circuits
    • Hand drawing curve tool and FOURIER tool (harmonics synthesis)
    • TC.ACS provides an extensive safety concept in order to detect unwanted or off-limit conditions very quickly and to initiate controlled limiting or even a shutdown.

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

    • 12GHz RF analog signal generator
    • AM, FM, PM, Sweep & Pulse Modulation
    • Exceptionally Low Phase Noise of -145dBc/Hz @100MHz and 10@kHz offset
    • Field ready, with 10” touch screen suited for day and night use and 2 hour battery operation
    • Remotely programmable via MATLAB, Python, LabVIEW and other software programming environments.
    • Removable uSD card for instrument security

     

    • 6GHz RF analog signal generator
    • AM, FM, PM, Sweep & Pulse Modulation
    • Exceptionally Low Phase Noise of -145dBc/Hz @100MHz and 10@kHz offset
    • Field ready, with 10” touch screen suited for day and night use and 2 hour battery operation
    • Remotely programmable via MATLAB, Python, LabVIEW and other software programming environments.
    • Removable uSD card for instrument security

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 60,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 166.7 / 83.3 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 527/240 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 125.0 / 62.5  (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 27 (U) and Weight 466/212 (LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models Including Cabinets

    Rated Power 30,000 (vA),  Output Power 21,000(w)  Output form  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS 25.0/13.9 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 15 (U) and Weight 320/146(LBS./KG).

     

  • AC, DC, AC+DC, Single and Three – Phase -Models without Cabinets

    Rated Power  12000 (vA),  Outputform  1,2,3Ø, Output Volt-Max 300(L-N)/425 (VAC/VDC)(1), Output AMPS/PHS  33.3/16.7 (AAC/ADC)(2), Input Power Form (3) 3 Ø, Panel Height (4) 4 (U) and Weight 112/51 (LBS./KG).

     

  • Photovoltaic applications, the quality and technical data of the AC-DC converter is of primary interest. Solar installations are intended for a lifetime of roughly 20 years, therefore even fractions of a percent in efficiency will represent significant amounts of energy losses.

  • Programmable Grid-tie Sink High-Power DC Supply,

  • Programmable Grid-tie Source & Sink Technology
    Wide range of power 20 to 512 kW, expandable up to several MW
    DC output voltages from 0-65 VDC up to 0-1500 VDC, +/- 40 A up to +/- 600 A