1 800 665 7301 | info@tmetrix.com

    • Easily create tasks
    • Obtain fast results
    • Adapts to the user’s needs and skills level
    • Reduces working time
    • Saves money!
    • Designed to operate with maximum intelligence
    • Automates workflows
    • Enables autonomous measurements

     

  • Robust RF Test on PCB and Ceramic

    • Replace costly and inflexible test fixtures with easy-to-use probe tips
    • Long lifetime – typically over 1,000,000 contacts
    • GS/SG footprint up to 4 GHz and GSG up to 20 GHz
    • High-power RF test: up to 30 Watts
    • Test at temperatures from -60°C to 200°C

     

  • High power, High performance probe

    • High power – 66 W at 2.4 GHz and 43 W at 5 GHz
    • Extremely low insertion loss of ≤ 0.4 dB (typical) up to 40 GHz
    • Excellent contact control and low contact resistance
    • High performance on any pad material (Al or Au)
    • Longest lifetime – typically one million (1,000,000) touchdowns

     

  • Excellent Performance – Longest Lifetime

    • Best price per contact – typically over one million (1,000,000) touchdowns
    • RF/Microwave signal is shielded and completely air isolated in the probe body
    • Excellent performance in vacuum environments and temperatures as low as 4 K, or as high as 300°C
    • Highest impedance control with perfectly-symmetrical, MEMS-machined coplanar contact structure
    • Probe on any pad material with minimal damage

     

    • Highest accuracy in test results
    • Easy setup even for less experienced users
    • Minimized coupling losses with minimal trench dimensions
    • Exclusive FormFactor-developed automated test methodology
    • Wide range of tools for capturing, logging and interpreting data
    • Enables hands-free autonomous calibration and re-calibration at multiple temperatures
    • Search First Light feature enables automated determination of initial position for optimization
    • Once aligned, all calibration functions are automated and performed through SiPh-Tool

     

  • The new G5.RSS series features

    • High control dynamics
    • An exceptional accuracy
    • A nominal output voltage of up to 3000 VDC
    • A wide current-voltage range with an auto-ranging factor of 3.
    • You get the best value for your investment.

     

  • Key Performance Capabilities:

    • Slew rates up to 60 V/µsec.
    • Up to 240A DC at +50VDC or –50VDC (4301-240 configuration).
    • Can provide pulses of up to 800 amps at voltages of up to ±100V (4301-240 configuration).
    • Adjustable compensation allows the system to maintain a 50V/2 µsec rise-time over a wide range of current outputs.

     

  • Key Performance Capabilities:

    • Bandwidth: DC to 50 kHz
    • Voltage: 0 to 250 VRMS; 0 to 350 VDC
    • Current: 100 to 500 ARMS
    • Distortion: 0.1%
    • Power: 4 kW to 20 kW*Power levels up to 5X rated power when driving reactive loads
    • High power efficiency and density

    *Models available with output from 4 kW to 20 kW (capable of up to 125 kVA).

     

  • Key Performance Capabilities:

    • 4-Quadrant – Can source and sink current
    • ±80V – DC supply for 12V to 48V systems; meets 80V surge requirements
    • 300 kHz Sine – DC ripple tests for all major standards
    • 3µs Rise Time – Exceeds surge and dropout slew rate requirements
    • 3mΩ DC Source Impedance – Out-performs ISO 7637-2 requirements
    • Supports ground reference and supply offset testing required for ISO 16750-2 Sect. 4.8 and other similar standards

     

  • Key Performance Capabilities:

    • Up to 900 watts RMS power output (7136 model)
    • Small signal response up to 400 kHz
    • User-adjustable precision DC offset
    • User-adjustable current limit: 1A to 25A
    • 4-quadrant operation
    • AC/DC coupled

     

  • Key Performance Capabilities:

    • Up to 900 watts RMS power output (7136 model)
    • Small signal response up to 400 kHz
    • User-adjustable precision DC offset
    • User-adjustable current limit: 1A to 25A
    • 4-quadrant operation
    • AC/DC coupled

     

    • On-wafer power device characterization up to 10,000 V DC / 600 A
    • Reduced probe and device destruction at high currents up to 20 A DC and 300 A pulse
    • Prevent thin wafers from curling and breaking
    • Accurate Rds(on) measurement at high current
    • Accurate UIS measurements at high temperature
    • Roll-out stage for full wafer access and easy wafer loading/unloading
    • Seamless integration between Velox and analyzers/measurement software
    • High-throughput wafer autoloading (standard, thinned, warped, TAIKO)
    • Easy on-screen navigation, wafer mapping, and operation of accessories with Velox
  • Enabling single-contact high-current/high-voltage test

    • Enables coaxial measurements up to 10,000 V and 300 A pulsed (600 A in a parallel configuration) with a single touchdown
    • Even distribution of high current with innovative multi-fingertip design
    • Compatible with Tesla 200/300 mm power device characterization system
    • Reduced measurement time by testing both high-voltage and high-current conditions with a single touchdown
    • Accurate characterization of a wide range of pad sizes and test currents, with minimum pad damage and contact resistance
    • Safe, reliable and repeatable high-current/voltage measurements over a wide temperature range (from -55°C to +300°C)

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Bidirectional (source & sink), Regenerative 0…65VDC to 0…1500VDC, 20kW up to 1.5 MW 

    • cell system nominal voltage and type of chemistry
    • number of cells
    • internal resistance and associated parameters
    • cell temperature progression
    • allowed current
    • charge efficiency
    • energy computing and management facilities
    • time-dependent and functional dependent parameters

     

    • Setting of operational parameters for each output phase: (frequency, phase, voltage, basic waveform)
    • Defining functional blocks enabling a wide variety of modulation capabilities
    • Defining, editing and storing of even complex and long test sequences
    • Preview window for output voltage waveforms
    • LC load mode, definition of complex equivalent circuits
    • Hand drawing curve tool and FOURIER tool (harmonics synthesis)
    • TC.ACS provides an extensive safety concept in order to detect unwanted or off-limit conditions very quickly and to initiate controlled limiting or even a shutdown.