1 800 665 7301 | info@tmetrix.com

  • A powerful Windows-based software package for managing and analyzing TDR data from CT100 Series and other TDR instruments.

    Key Features:

    • Archive, analyze, and compare TDR waveforms with ease
    • Compatible with CT100 Series TDRs and other instruments via CSV import
    • Live LAN/WAN/Internet streaming and remote control of CT100 units
    • Powerful tools for QA/QC, fault detection, and cable performance tracking
    • Supports SQL database storage and flexible file management
    • Includes advanced transforms: subtraction, derivative, and averaging
    • Fine-tune velocity of propagation (VoP) up to 6 significant digits

     

  • The industry’s highest-resolution portable TDR cable tester, the MOHR CT100 delivers unmatched accuracy for coaxial and twisted-pair cables in the field, lab, or production floor.

    Key Features:

    • Resolves connector details < 1 cm (8–10x sharper than competitors)
    • Tests coaxial, twisted-pair, and multi-conductor cables
    • Exceeds Tektronix® 1502C TDR specifications
    • Accurate impedance and cable length measurement with 16-bit ADC
    • Detects intermittent faults with up to 250,000 samples/sec
    • Integrated LAN/WAN/Internet remote control with CT Viewer™ 2 software
    • Lightweight, portable design with 4.3″ color LCD
    • Used by the U.S. Navy as the Tektronix 1502 series replacement

     

  • A professional-grade video generator designed for testing Dolby Vision, HDR, and DSC on DisplayPort™ 1.4a sink devices. Ideal for R&D debugging, compliance testing, and high-resolution validation.

    Key Features:

    • Supports 8K @ 30 Hz and 4K @ 120 Hz resolutions (8K @ 60 Hz with DSC)
    • DP 1.4a Link Layer CTS tool for sink testing*
    • HDCP 2.2/2.3 CTS tool for transmitter compliance*
    • HDR and Dolby Vision test capability with 32 GB extended memory
    • Supports DSC, FEC, LTTPR, and MST (4 streams)
    • USB-C output with included converter
    • No restrictions on video format, audio format, frame rate, or infoframes

     

  • A versatile and cost-effective interoperability test solution for HDMI 1.4 source devices, designed to streamline R&D debugging and automated testing.

    Key Features:

    • HDMI 1.4 and DisplayPort interface support
    • Compatible with TSI Test System Interface API
    • Ready-made test routines for streamlined functionality testing
    • Comprehensive analysis of video, audio, CEC, and metadata
    • Ideal for testing Blu-Ray players, laptops, set-top boxes, game consoles, and tablets
    • Supports both R&D debugging and test automation environments

     

  • The new G5.RSS series features

    • High control dynamics
    • An exceptional accuracy
    • A nominal output voltage of up to 3000 VDC
    • A wide current-voltage range with an auto-ranging factor of 3.
    • You get the best value for your investment.

     

  • The Hi-Techniques FreeStyle series of Data Acquisition Systems is a versatile, capable solution for mobile and rugged data acquisition applications. FreeStyle was designed from the ground up to make data acquisition as fast and as easy as possible. Just grab your FreeStyle and your computer and head out to the test site.

    Flexibility by Design

     

  • The Hi-Techniques Synergy series of Data Acquisition Systems integrates superior transient and streaming capability with optimized time and frequency domain performance. Add in universal signal conditioning, real-time math and you’ll see why Synergy is the ultimate Data Acquisition System for all of your mechanical, electrical, acoustic, shock and vibration measurements.

     

  • The Hi-Techniques Synergy series of Data Acquisition Systems integrates superior transient and streaming capability with optimized time and frequency domain performance. Add in universal signal conditioning, real-time math and you’ll see why Synergy is the ultimate Data Acquisition System for all of your mechanical, electrical, acoustic, shock and vibration measurements.

     

  • High‐Resolution Portable TDR with Frequency‐Domain Analysis Tools

    Ideal for testing all types of microwave/RF and digital cables and connectors

    • Rugged portable TDR with S‐parameter tools
    • Resolves connector detail (<1 cm)
    • 75 μm (0.003 in.) cursor resolution
    • 16‐bit digital sampling at up to 250 KSPS
    • Stores thousands of TDR traces
    • USB host/client, 10/100 Ethernet
    • Lightweight, bright color screen
    • Internet streaming and remote control

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Bidirectional (source & sink), Regenerative 0…65VDC to 0…1500VDC, 20kW up to 1.5 MW 

    • cell system nominal voltage and type of chemistry
    • number of cells
    • internal resistance and associated parameters
    • cell temperature progression
    • allowed current
    • charge efficiency
    • energy computing and management facilities
    • time-dependent and functional dependent parameters

     

    • Setting of operational parameters for each output phase: (frequency, phase, voltage, basic waveform)
    • Defining functional blocks enabling a wide variety of modulation capabilities
    • Defining, editing and storing of even complex and long test sequences
    • Preview window for output voltage waveforms
    • LC load mode, definition of complex equivalent circuits
    • Hand drawing curve tool and FOURIER tool (harmonics synthesis)
    • TC.ACS provides an extensive safety concept in order to detect unwanted or off-limit conditions very quickly and to initiate controlled limiting or even a shutdown.

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Photovoltaic applications, the quality and technical data of the AC-DC converter is of primary interest. Solar installations are intended for a lifetime of roughly 20 years, therefore even fractions of a percent in efficiency will represent significant amounts of energy losses.

  • Programmable Grid-tie Sink High-Power DC Supply,