1 800 665 7301 | info@tmetrix.com

  • The new G5.RSS series features

    • High control dynamics
    • An exceptional accuracy
    • A nominal output voltage of up to 3000 VDC
    • A wide current-voltage range with an auto-ranging factor of 3.
    • You get the best value for your investment.

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +12 to -12 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510 MCOR12 Power Modules are identical and interchangeable.
    • Has two high-precision measurements of output current;
      • one is used to close the regulation control loop,
      • provides an independent monitoring signal to the Crate Interface Card.
    • Fault sensing circuitry in the module sets a Fault Latch which inhibits the output.
    • A (momentary) Sync input signal inhibits MOSFET switching when it is active (high);
      • this eliminate switching noise .
      • reduces power line noise during sensitive analog signal measurements.

     

    • Proven member of a modular Power Module family, more than 800 units are in service
    • Precision-regulated Bi-Polar output provides up to +30 to -30 Amps for Magnet loads.
    • Smooth operation through zero amps output current, no “Crossover” problems.
    • All 2510R30 MCOR30 Power Modules are identical and interchangeable
      • Programming Card is plugged into the replacement module.
    • Each channel has a critically-damped, LC noise filter with a cut-off frequency of about 8 kHz.
    • A 16-pin front panel diagnostics connector taps onto major circuit nodes which enables quick “inthe-crate” fault evaluation

     

    • 2U Chassis – 19″ rack mount 3.48” Height, 9.60” Depth and Weight 6lb.
    • Power 120V AC 60Hz
    • Washable front removable air filter
    • Ball Bearing AC fans provide 330 CFM
    • Dual plenum design
    • Cooling for 160mm,220mm depth modules
    • Diverts lower warmed air to rear of Cabinet
    • RM option diverts lower air to front of Cabinet

     

    • accommodate these control schemes
    • total control system interface on a single VME-standard card
    • occupies the left-most slot of the crate
    • monitoring voltage reference inputs, output voltages and fault conditions
    • standard VMEbus-compatible 6U by 220 mm board installed
    • Eurocard crate
    • Two 96-pin I/O connectors

     

  • MCOR Modules

    MCOR 2/6/9/12

    Each module can be customized to provide maximum outputs of 2 amps, 6 amps, 9 amps, and 12 amps. Up to 16 of these can fit in a single 6U VME style crate.

    MCOR 30

    Each module can provide a maximum output 30 amps. Up to 8 of these can fit in a single 6U VME style crate.

  • The Hi-Techniques FreeStyle series of Data Acquisition Systems is a versatile, capable solution for mobile and rugged data acquisition applications. FreeStyle was designed from the ground up to make data acquisition as fast and as easy as possible. Just grab your FreeStyle and your computer and head out to the test site.

    Flexibility by Design

     

  • The Hi-Techniques Synergy series of Data Acquisition Systems integrates superior transient and streaming capability with optimized time and frequency domain performance. Add in universal signal conditioning, real-time math and you’ll see why Synergy is the ultimate Data Acquisition System for all of your mechanical, electrical, acoustic, shock and vibration measurements.

     

  • The Hi-Techniques Synergy series of Data Acquisition Systems integrates superior transient and streaming capability with optimized time and frequency domain performance. Add in universal signal conditioning, real-time math and you’ll see why Synergy is the ultimate Data Acquisition System for all of your mechanical, electrical, acoustic, shock and vibration measurements.

     

    • provides precision bi-polar output currents
    • minimal zero-cross over distortion
    • 19” rack mounted 6U x 220 mm crate
    • crate has 17 slots; 16 (slot 0 thru 15)
    • connectors
      • J1 (ExtIntlk),
      • J2 (CrateOK),
      • J3 (Input Reference Voltages),
      • J4 (Output Monitors), and
      • J9 (Bitbus)

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Bidirectional (source & sink), Regenerative 0…65VDC to 0…1500VDC, 20kW up to 1.5 MW 

    • cell system nominal voltage and type of chemistry
    • number of cells
    • internal resistance and associated parameters
    • cell temperature progression
    • allowed current
    • charge efficiency
    • energy computing and management facilities
    • time-dependent and functional dependent parameters

     

    • Setting of operational parameters for each output phase: (frequency, phase, voltage, basic waveform)
    • Defining functional blocks enabling a wide variety of modulation capabilities
    • Defining, editing and storing of even complex and long test sequences
    • Preview window for output voltage waveforms
    • LC load mode, definition of complex equivalent circuits
    • Hand drawing curve tool and FOURIER tool (harmonics synthesis)
    • TC.ACS provides an extensive safety concept in order to detect unwanted or off-limit conditions very quickly and to initiate controlled limiting or even a shutdown.

     

    • compact and completely modular design
    • high effectiveness in all operation modes, few requirements on building infrastructure
    • ability to use an existing liquid cooling system directly
    • optional matched liquid-to-air cooling unit TC.LAE available
    • possibility of upgrading to systems of up to 1 MVA
    • high level of system dynamics, ≤ 5 kHz modulation bandwidth
    • non-restrictive capability of refeeding in the Q4 operation mode
    • possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
    • possibility of “Hardware-in-the loop”-operation (HIL mode)
    • user friendly application software with pre-configured test patterns
    • possibility of integrating into a complete SAS simulation and test system
    • galvanic isolation available as an option without derating the simulator port data

     

  • Phase -Models Kitted for installation into End User’s Cabinet  and Phase -Models including Cabinet and Emergency Power off  (EPO)1